{"product_id":"goodman-2-ton-21-width-upflow-downflow-cased-evaporator-coil-txv-r32","title":"Goodman - 2 Ton - 21\" Width Upflow\/Downflow Cased Evaporator Coil TXV - R32 - CAPTA2422C3","description":"\u003ch2\u003e\u003cspan\u003eGoodman - 2 Ton - 21\" Width Upflow\/Downflow Cased Evaporator Coil TXV - R32 - CAPTA2422C3\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAn AC or heat pump system is only as good as its evaporator coil. The Goodman CAPTA evaporator coils are designed with this simple thought in mind for its longevity, accessibility, and value as their other heating and cooling equipment. The advanced design and all-aluminum constriction of this coil improves its durability and heat transfer efficiency. The CAPTA series are cased A-Coils for use in Upflow\/Downflow applications. These units include an internal TXV (thermostatic expansion valve), which is perfect for high-performance systems. Goodman pressure tests each coil twice prior to it leaving the factory. Whether you are replacing an old failing coil or installing a new system, you can choose Goodman's CAPTA units with confidence.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAll-Aluminum Coil: Goodman's evaporator coils maximize surface area and optimize heat transfer for efficient comfort by using a reliable all-aluminum design complete with sine fins and grooved tubes.\u003c\/li\u003e\n\u003cli\u003eInternal Thermostatic Expansion Valve: Goodman's CAPTA units have a factory-installed internal thermostatic expansion valve, which streamlines installation and maintains ideal refrigerant flow for your system.\u003c\/li\u003e\n\u003cli\u003eCabinet Durability: Providing superior longevity and efficiency, CAPTA units have a galvanized, embossed, and insulated cabinet that protects the coil and prevents air leakage.\u003c\/li\u003e\n\u003cli\u003eCondensate Management: Keeping your system sage and operational, the CAPTA units feature a foil-faced insulation to inhibit the formation of condensate and a rust-resistant, DecaBDE-free thermoplastic drain pan secondary drain connections. The drain pan is UV-resistant.\u003c\/li\u003e\n\u003cli\u003eR32 Compatibility: Complies with Clean Air Act New Refrigerant Requirements.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-cly1{text-align:left;vertical-align:middle}\n.tg .tg-wa1i{font-weight:bold;text-align:center;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" class=\"tg-wa1i\"\u003e2 Ton 21\" Width Goodman Upflow\/Downflow Cased Evaporator Coil - TXV - R32\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSKU\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eCAPTA2422C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWeight (in lbs)\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e43.000000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eBrand\/Manufacturer\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGoodman\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eUpflow \/ Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eLiquid Line\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSuction Line\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eTonnage\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e2 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eStyle\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eA-Coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eCertification\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eETL Listed, AHRI Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e22\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eManual\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman_Vertical_Coil_Install_Manual_v3.2023.pdf?v=1725699589\" target=\"_blank\"\u003e\u003cstrong\u003eInstallation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman-CAPTA32-coil_Spec_Shet.pdf?v=1725699589\" target=\"_blank\"\u003e\u003cstrong\u003eSpec Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"h4mkuu\" data-start=\"27\" data-end=\"344\"\u003e\n\u003cp data-start=\"29\" data-end=\"344\"\u003e\u003cstrong data-start=\"29\" data-end=\"74\"\u003ePurpose‑Built for R‑32 Split HVAC Systems\u003c\/strong\u003e\u003cbr data-start=\"74\" data-end=\"77\"\u003eThe \u003cstrong data-start=\"83\" data-end=\"128\"\u003eGoodman CAPTA2422C3 2 Ton Evaporator Coil\u003c\/strong\u003e is engineered specifically for \u003cstrong data-start=\"160\" data-end=\"193\" data-is-only-node=\"\"\u003eR‑32 refrigerant applications\u003c\/strong\u003e, ensuring modern refrigerant compatibility and long‑lasting performance when paired with the right outdoor unit. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1vfmckl\" data-start=\"346\" data-end=\"648\"\u003e\n\u003cp data-start=\"348\" data-end=\"648\"\u003e\u003cstrong data-start=\"348\" data-end=\"401\"\u003eFactory‑Installed TXV for Precise Cooling Control\u003c\/strong\u003e\u003cbr data-start=\"401\" data-end=\"404\"\u003eA \u003cstrong data-start=\"408\" data-end=\"455\"\u003ebuilt‑in thermostatic expansion valve (TXV)\u003c\/strong\u003e delivers \u003cstrong data-start=\"465\" data-end=\"498\" data-is-only-node=\"\"\u003eaccurate refrigerant metering\u003c\/strong\u003e, enhancing cooling efficiency, improving humidity control, and helping your system maintain consistent comfort. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1tlfd6f\" data-start=\"650\" data-end=\"915\"\u003e\n\u003cp data-start=\"652\" data-end=\"915\"\u003e\u003cstrong data-start=\"652\" data-end=\"711\"\u003eAll‑Aluminum Coil for Better Heat Transfer \u0026amp; Durability\u003c\/strong\u003e\u003cbr data-start=\"711\" data-end=\"714\"\u003eThe \u003cstrong data-start=\"720\" data-end=\"752\"\u003eall‑aluminum tubing and fins\u003c\/strong\u003e maximize heat transfer and resist corrosion—supporting reliable operation and long service life in residential environments. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1h08uvw\" data-start=\"917\" data-end=\"1198\"\u003e\n\u003cp data-start=\"919\" data-end=\"1198\"\u003e\u003cstrong data-start=\"919\" data-end=\"960\"\u003eFlexible Upflow\/Downflow Installation\u003c\/strong\u003e\u003cbr data-start=\"960\" data-end=\"963\"\u003eDesigned for both \u003cstrong data-start=\"983\" data-end=\"1021\"\u003eupflow and downflow configurations\u003c\/strong\u003e, this coil fits a wide range of HVAC setups (attics, closets, basements) and matches standard \u003cstrong data-start=\"1116\" data-end=\"1138\" data-is-only-node=\"\"\u003e21″ cabinet widths\u003c\/strong\u003e for easy integration. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"186149b\" data-start=\"1200\" data-end=\"1466\"\u003e\n\u003cp data-start=\"1202\" data-end=\"1466\"\u003e\u003cstrong data-start=\"1202\" data-end=\"1239\"\u003eSmart Condensate \u0026amp; Cabinet Design\u003c\/strong\u003e\u003cbr data-start=\"1239\" data-end=\"1242\"\u003eFoil‑faced insulation reduces cabinet condensation, while \u003cstrong data-start=\"1302\" data-end=\"1390\"\u003erust‑resistant thermoplastic drain pans with secondary connections and UV protection\u003c\/strong\u003e help prevent moisture‑related issues. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"irbsat\" data-start=\"1468\" data-end=\"1701\"\u003e\n\u003cp data-start=\"1470\" data-end=\"1701\"\u003e\u003cstrong data-start=\"1470\" data-end=\"1499\"\u003eService‑Friendly Features\u003c\/strong\u003e\u003cbr data-start=\"1499\" data-end=\"1502\"\u003eA \u003cstrong data-start=\"1506\" data-end=\"1572\"\u003esingle front access panel and standardized copper suction stub\u003c\/strong\u003e simplify inspection, maintenance, and refrigerant line connections for HVAC professionals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"83\" data-end=\"363\"\u003e\u003cstrong data-start=\"83\" data-end=\"138\"\u003eQ1: What HVAC systems is this coil compatible with?\u003c\/strong\u003e\u003cbr data-start=\"138\" data-end=\"141\"\u003eA: The \u003cstrong data-start=\"148\" data-end=\"171\"\u003eGoodman CAPTA2422C3\u003c\/strong\u003e is designed for \u003cstrong data-start=\"188\" data-end=\"246\"\u003e1.5–2 ton split‑system air conditioners and heat pumps\u003c\/strong\u003e, making it suitable for residential cooling and heat pump indoor applications. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"365\" data-end=\"619\"\u003e\u003cstrong data-start=\"365\" data-end=\"414\"\u003eQ2: Does this coil include a metering device?\u003c\/strong\u003e\u003cbr data-start=\"414\" data-end=\"417\"\u003eA: Yes — it includes a \u003cstrong data-start=\"440\" data-end=\"496\"\u003efactory‑installed TXV (Thermostatic Expansion Valve)\u003c\/strong\u003e that provides precise refrigerant metering for both cooling and heat pump operation. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"621\" data-end=\"829\"\u003e\u003cstrong data-start=\"621\" data-end=\"668\"\u003eQ3: Which refrigerant is it engineered for?\u003c\/strong\u003e\u003cbr data-start=\"668\" data-end=\"671\"\u003eA: This model is optimized for \u003cstrong data-start=\"702\" data-end=\"722\"\u003eR‑32 refrigerant\u003c\/strong\u003e, supporting modern HVAC systems with lower global warming potential. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"831\" data-end=\"1051\"\u003e\u003cstrong data-start=\"831\" data-end=\"872\"\u003eQ4: What installations are supported?\u003c\/strong\u003e\u003cbr data-start=\"872\" data-end=\"875\"\u003eA: It supports \u003cstrong data-start=\"890\" data-end=\"927\"\u003eupflow and downflow installations\u003c\/strong\u003e, offering flexibility for vertical duct configurations with furnaces or air handlers. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1053\" data-end=\"1269\"\u003e\u003cstrong data-start=\"1053\" data-end=\"1098\"\u003eQ5: What are the key physical dimensions?\u003c\/strong\u003e\u003cbr data-start=\"1098\" data-end=\"1101\"\u003eA: The coil cabinet measures about \u003cstrong data-start=\"1136\" data-end=\"1170\"\u003e21″ wide × 21″ deep × 22″ high\u003c\/strong\u003e, with standard \u003cstrong data-start=\"1186\" data-end=\"1230\"\u003e3\/8″ liquid and 3\/4″ suction connections\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1271\" data-end=\"1618\"\u003e\u003cstrong data-start=\"1271\" data-end=\"1335\"\u003eQ6: What construction and durability features does it offer?\u003c\/strong\u003e\u003cbr data-start=\"1335\" data-end=\"1338\"\u003eA: It features an \u003cstrong data-start=\"1356\" data-end=\"1388\"\u003eall‑aluminum evaporator coil\u003c\/strong\u003e in a \u003cstrong data-start=\"1394\" data-end=\"1433\"\u003egalvanized, insulated cased cabinet\u003c\/strong\u003e, \u003cstrong data-start=\"1435\" data-end=\"1483\"\u003efoil‑faced insulation to reduce condensation\u003c\/strong\u003e, and \u003cstrong data-start=\"1489\" data-end=\"1579\"\u003erust‑resistant, UV‑protected thermoplastic drain pans with secondary drain connections\u003c\/strong\u003e. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1620\" data-end=\"1827\"\u003e\u003cstrong data-start=\"1620\" data-end=\"1674\"\u003eQ7: Is this coil certified for quality and safety?\u003c\/strong\u003e\u003cbr data-start=\"1674\" data-end=\"1677\"\u003eA: Yes — the CAPTA2422C3 is \u003cstrong data-start=\"1705\" data-end=\"1738\"\u003eAHRI certified and ETL listed\u003c\/strong\u003e to meet industry performance and safety standards.\u003c\/p\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\n\u003cbr\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"ifz7ft\" data-start=\"108\" data-end=\"276\"\u003e\n\u003cp data-start=\"110\" data-end=\"276\"\u003e\u003cstrong data-start=\"110\" data-end=\"150\"\u003eReplace Air Filters Every 1–3 Months\u003c\/strong\u003e – Clean filters ensure proper airflow across the all‑aluminum coil, improving cooling efficiency and preventing coil icing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"h2v5jw\" data-start=\"278\" data-end=\"569\"\u003e\n\u003cp data-start=\"280\" data-end=\"569\"\u003e\u003cstrong data-start=\"280\" data-end=\"307\"\u003eClean the Coil Annually\u003c\/strong\u003e – Dust and debris on coil fins reduce heat transfer; schedule professional cleaning to maintain SEER2 performance. (\u003ca data-start=\"424\" data-end=\"566\" rel=\"noopener\" class=\"decorated-link cursor-pointer\"\u003ehvacstore.com\u003cspan aria-hidden=\"true\" class=\"ms-0.5 inline-block align-middle leading-none\"\u003e\u003csvg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"20\" height=\"20\" aria-hidden=\"true\" data-rtl-flip=\"\" class=\"block h-[0.75em] w-[0.75em] stroke-current stroke-[0.75]\"\u003e\u003cuse fill=\"currentColor\" href=\"\/cdn\/assets\/sprites-core-fk4oovux.svg#304883\"\u003e\u003c\/use\u003e\u003c\/svg\u003e\u003c\/span\u003e\u003c\/a\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"t1eqwm\" data-start=\"571\" data-end=\"684\"\u003e\n\u003cp data-start=\"573\" data-end=\"684\"\u003e\u003cstrong data-start=\"573\" data-end=\"607\"\u003eInspect Condensate Drain \u0026amp; Pan\u003c\/strong\u003e – Keep the drain pan and line clear to prevent leaks and microbial growth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1xzr3r3\" data-start=\"686\" data-end=\"845\"\u003e\n\u003cp data-start=\"688\" data-end=\"845\"\u003e\u003cstrong data-start=\"688\" data-end=\"711\"\u003eCheck TXV Operation\u003c\/strong\u003e – The thermostatic expansion valve regulates refrigerant flow; periodic inspection ensures proper superheat and cooling efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1wpj1t4\" data-start=\"847\" data-end=\"963\"\u003e\n\u003cp data-start=\"849\" data-end=\"963\"\u003e\u003cstrong data-start=\"849\" data-end=\"882\"\u003eMaintain Unobstructed Airflow\u003c\/strong\u003e – Keep supply and return vents clear for optimal upflow or downflow operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1r5991l\" data-start=\"965\" data-end=\"1088\"\u003e\n\u003cp data-start=\"967\" data-end=\"1088\"\u003e\u003cstrong data-start=\"967\" data-end=\"999\"\u003eInspect Cabinet \u0026amp; Insulation\u003c\/strong\u003e – Check the galvanized, insulated cabinet annually for moisture, corrosion, or damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"tkn3mm\" data-start=\"1090\" data-end=\"1251\"\u003e\n\u003cp data-start=\"1092\" data-end=\"1251\"\u003e\u003cstrong data-start=\"1092\" data-end=\"1124\"\u003eSchedule Annual HVAC Service\u003c\/strong\u003e – Professional maintenance helps detect refrigerant issues, clean internal components, and maintain peak system performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":46812789702793,"sku":"CAPTA2422C3","price":509.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0759\/2443\/9177\/files\/download_5_756665ba-831b-4be8-9567-be702980f487.webp?v=1779806630","url":"https:\/\/mobility-ready.com\/products\/goodman-2-ton-21-width-upflow-downflow-cased-evaporator-coil-txv-r32","provider":"Supplies for Happy Tails","version":"1.0","type":"link"}