{"product_id":"goodman-2-ton-60-000-btu-80-afue-gas-furnace-and-air-conditioner-system-upflow-14-5-seer2-r32-2","title":"Goodman - 2 Ton\/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Upflow - 14.5 SEER2 - R32 - CAPTA3022A3","description":"\u003ch2\u003e\u003cspan\u003eGoodman - 2 Ton\/60,000 BTU 80% AFUE Gas Furnace and Air Conditioner System - Upflow - 14.5 SEER2 - R32 - CAPTA3022A3 \u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe GR9T800603AN Goodman gas furnace features high-quality construction and efficient operation at a great value. The GR9T800603AN two-stage, 9-speed furnace utilizes Goodman's superior heat exchanger design to provide efficient, reliable heating to your home. If you're looking to cut your energy bills and improve your comfort without breaking the bank, your search stops with the Goodman GR9T800603AN.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAll-Aluminum Coil: Goodman's evaporator coils maximize surface area and optimize heat transfer for efficient comfort by using a reliable all-aluminum design complete with sine fins and grooved tubes.\u003c\/li\u003e\n\u003cli\u003eInternal Thermostatic Expansion Valve: Goodman's CAPTA units have a factory-installed internal thermostatic expansion valve, which streamlines installation and maintains ideal refrigerant flow for your system.\u003c\/li\u003e\n\u003cli\u003eCabinet Durability: Providing superior longevity and efficiency, CAPTA units have a galvanized, embossed, and insulated cabinet that protects the coil and prevents air leakage.\u003c\/li\u003e\n\u003cli\u003eCondensate Management: Keeping your system sage and operational, the CAPTA units feature a foil-faced insulation to inhibit the formation of condensate and a rust-resistant, DecaBDE-free thermoplastic drain pan secondary drain connections. The drain pan is UV-resistant.\u003c\/li\u003e\n\u003cli\u003eR32 Compatibility: Complies with Clean Air Act New Refrigerant Requirements.\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-cly1{text-align:left;vertical-align:middle}\n.tg .tg-wa1i{font-weight:bold;text-align:center;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-wa1i\"\u003eSKU\u003c\/th\u003e\n\u003cth class=\"tg-cly1\"\u003eGLXS5BA2410 \/ CAPTA3022A3 \/ GR9T800603AN\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWeight (in lbs)\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e0.000000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eAHRI Certificate Number\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e215380233\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eExhaust Flue Requirement\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eMetal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eBrand\/Manufacturer\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGoodman\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eFurnace Efficiency \/ AFUE\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e80%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSEER2 (Efficiency)\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e14.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eCondenser Stages\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eSingle Stage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSystem Tonnage\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e2 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\u003cstrong\u003eWhat our Experts Think\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"1m55qw\" data-start=\"27\" data-end=\"212\"\u003e\n\u003cp data-start=\"29\" data-end=\"212\"\u003e\u003cstrong data-start=\"29\" data-end=\"61\"\u003eBalanced year‑round comfort:\u003c\/strong\u003e Combines a \u003cstrong data-start=\"73\" data-end=\"110\"\u003e2‑ton (60,000 BTU) cooling system\u003c\/strong\u003e with an \u003cstrong data-start=\"119\" data-end=\"143\" data-is-only-node=\"\"\u003e80% AFUE gas furnace\u003c\/strong\u003e, providing dependable \u003cstrong data-start=\"166\" data-end=\"189\"\u003eheating and cooling\u003c\/strong\u003e in one matched system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"r7v0h0\" data-start=\"214\" data-end=\"425\"\u003e\n\u003cp data-start=\"216\" data-end=\"425\"\u003e\u003cstrong data-start=\"216\" data-end=\"245\"\u003eSolid energy performance:\u003c\/strong\u003e \u003cstrong data-start=\"246\" data-end=\"279\"\u003e14.5 SEER2 cooling efficiency\u003c\/strong\u003e offers \u003cstrong data-start=\"287\" data-end=\"316\" data-is-only-node=\"\"\u003enoticeable energy savings\u003c\/strong\u003e over older systems, while 80% AFUE delivers \u003cstrong data-start=\"361\" data-end=\"394\"\u003epractical heating performance\u003c\/strong\u003e appropriate for many climates.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"qng9mo\" data-start=\"427\" data-end=\"594\"\u003e\n\u003cp data-start=\"429\" data-end=\"594\"\u003e\u003cstrong data-start=\"429\" data-end=\"458\"\u003eR‑32 refrigerant benefit:\u003c\/strong\u003e Uses \u003cstrong data-start=\"464\" data-end=\"491\"\u003emodern R‑32 refrigerant\u003c\/strong\u003e for \u003cstrong data-start=\"496\" data-end=\"563\" data-is-only-node=\"\"\u003eimproved thermal efficiency and a lower environmental footprint\u003c\/strong\u003e than many legacy refrigerants.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1qzbwn8\" data-start=\"596\" data-end=\"761\"\u003e\n\u003cp data-start=\"598\" data-end=\"761\"\u003e\u003cstrong data-start=\"598\" data-end=\"630\"\u003eEfficient, simple operation:\u003c\/strong\u003e The \u003cstrong data-start=\"635\" data-end=\"674\"\u003esingle‑stage compressor and furnace\u003c\/strong\u003e provide \u003cstrong data-start=\"683\" data-end=\"724\" data-is-only-node=\"\"\u003estraightforward, reliable performance\u003c\/strong\u003e with fewer components that can fail.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1nvw5jx\" data-start=\"763\" data-end=\"898\"\u003e\n\u003cp data-start=\"765\" data-end=\"898\"\u003e\u003cstrong data-start=\"765\" data-end=\"783\"\u003eUpflow design:\u003c\/strong\u003e \u003cstrong data-start=\"784\" data-end=\"806\"\u003eUpflow orientation\u003c\/strong\u003e fits most standard installations and duct systems in attics, basements, or utility closets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\u003cstrong\u003eQ\u0026amp;A\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp data-start=\"63\" data-end=\"276\"\u003e\u003cstrong data-start=\"63\" data-end=\"129\"\u003eQ: What heating and cooling capacity does this system deliver?\u003c\/strong\u003e\u003cbr data-start=\"129\" data-end=\"132\"\u003eA: The CAPTA3022A3 provides \u003cstrong data-start=\"160\" data-end=\"191\"\u003e2 tons (24,000 BTU) cooling\u003c\/strong\u003e and \u003cstrong data-start=\"196\" data-end=\"218\"\u003e60,000 BTU heating\u003c\/strong\u003e, ideal for \u003cstrong data-start=\"230\" data-end=\"275\"\u003esmall–medium homes and residential spaces\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"278\" data-end=\"469\"\u003e\u003cstrong data-start=\"278\" data-end=\"317\"\u003eQ: What are the efficiency ratings?\u003c\/strong\u003e\u003cbr data-start=\"317\" data-end=\"320\"\u003eA: The gas furnace offers \u003cstrong data-start=\"346\" data-end=\"359\"\u003e80 % AFUE\u003c\/strong\u003e efficiency, and the air conditioner delivers \u003cstrong data-start=\"405\" data-end=\"419\"\u003e14.5 SEER2\u003c\/strong\u003e, helping \u003cstrong data-start=\"429\" data-end=\"468\"\u003elower energy costs season‑to‑season\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"471\" data-end=\"651\"\u003e\u003cstrong data-start=\"471\" data-end=\"511\"\u003eQ: What refrigerant does the AC use?\u003c\/strong\u003e\u003cbr data-start=\"511\" data-end=\"514\"\u003eA: This system uses \u003cstrong data-start=\"534\" data-end=\"553\"\u003eR32 refrigerant\u003c\/strong\u003e, known for \u003cstrong data-start=\"565\" data-end=\"650\"\u003ebetter heat transfer, lower environmental impact, and improved energy performance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"653\" data-end=\"825\"\u003e\u003cstrong data-start=\"653\" data-end=\"703\"\u003eQ: What installation orientation is supported?\u003c\/strong\u003e\u003cbr data-start=\"703\" data-end=\"706\"\u003eA: Designed for \u003cstrong data-start=\"722\" data-end=\"745\"\u003eupflow installation\u003c\/strong\u003e, fitting \u003cstrong data-start=\"755\" data-end=\"792\"\u003estandard closets or utility areas\u003c\/strong\u003e in most residential HVAC setups.\u003c\/p\u003e\n\u003cp data-start=\"827\" data-end=\"985\"\u003e\u003cstrong data-start=\"827\" data-end=\"869\"\u003eQ: Is this a single‑stage HVAC system?\u003c\/strong\u003e\u003cbr data-start=\"869\" data-end=\"872\"\u003eA: Yes — both the furnace and air conditioner are \u003cstrong data-start=\"922\" data-end=\"938\"\u003esingle‑stage\u003c\/strong\u003e, providing \u003cstrong data-start=\"950\" data-end=\"984\"\u003esteady, dependable performance\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"987\" data-end=\"1148\"\u003e\u003cstrong data-start=\"987\" data-end=\"1031\"\u003eQ: What are the electrical requirements?\u003c\/strong\u003e\u003cbr data-start=\"1031\" data-end=\"1034\"\u003eA: The system operates on \u003cstrong data-start=\"1060\" data-end=\"1147\"\u003estandard residential power (115 V for furnace control; AC typically uses 208\/230 V)\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-start=\"1150\" data-end=\"1356\"\u003e\u003cstrong data-start=\"1150\" data-end=\"1215\"\u003eQ: Does the system include protective or durability features?\u003c\/strong\u003e\u003cbr data-start=\"1215\" data-end=\"1218\"\u003eA: Yes — it includes \u003cstrong data-start=\"1239\" data-end=\"1317\"\u003efactory‑installed safety switches, filter drier, and protective coil guard\u003c\/strong\u003e to help ensure \u003cstrong data-start=\"1333\" data-end=\"1355\"\u003esystem reliability\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003e\u003cstrong\u003eMaintenance Tips\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv class=\"flex flex-col text-sm pb-25\"\u003e\n\u003carticle class=\"text-token-text-primary w-full focus:outline-none [--shadow-height:45px] has-data-writing-block:pointer-events-none has-data-writing-block:-mt-(--shadow-height) has-data-writing-block:pt-(--shadow-height) [\u0026amp;:has([data-writing-block])\u0026gt;*]:pointer-events-auto scroll-mt-[calc(var(--header-height)+min(200px,max(70px,20svh)))]\" dir=\"auto\" data-turn-id=\"request-WEB:97376a74-33b5-4836-8f36-6e4c7b3d0a68-24\" data-testid=\"conversation-turn-16\" data-scroll-anchor=\"true\" data-turn=\"assistant\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"text-base my-auto mx-auto pb-10 [--thread-content-margin:var(--thread-content-margin-xs,calc(var(--spacing)*4))] @w-sm\/main:[--thread-content-margin:var(--thread-content-margin-sm,calc(var(--spacing)*6))] @w-lg\/main:[--thread-content-margin:var(--thread-content-margin-lg,calc(var(--spacing)*16))] px-(--thread-content-margin)\"\u003e\n\u003cdiv class=\"[--thread-content-max-width:40rem] @w-lg\/main:[--thread-content-max-width:48rem] mx-auto max-w-(--thread-content-max-width) flex-1 group\/turn-messages focus-visible:outline-hidden relative flex w-full min-w-0 flex-col agent-turn\" tabindex=\"-1\"\u003e\n\u003cdiv class=\"flex max-w-full flex-col gap-4 grow\"\u003e\n\u003cdiv data-message-author-role=\"assistant\" data-message-id=\"21b633c6-08cc-4e07-a282-8346c56153f3\" dir=\"auto\" data-message-model-slug=\"gpt-5-mini\" class=\"min-h-8 text-message relative flex w-full flex-col items-end gap-2 text-start break-words whitespace-normal [.text-message+\u0026amp;]:mt-1\"\u003e\n\u003cdiv class=\"flex w-full flex-col gap-1 empty:hidden\"\u003e\n\u003cdiv class=\"markdown prose dark:prose-invert w-full wrap-break-word light markdown-new-styling\"\u003e\n\u003cul data-start=\"91\" data-end=\"718\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"jfowzm\" data-start=\"91\" data-end=\"180\"\u003e\n\u003cp data-start=\"93\" data-end=\"180\"\u003e\u003cstrong data-start=\"93\" data-end=\"142\"\u003eReplace or clean air filters every 1–3 months\u003c\/strong\u003e to maintain airflow and efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1kcgqoa\" data-start=\"181\" data-end=\"260\"\u003e\n\u003cp data-start=\"183\" data-end=\"260\"\u003e\u003cstrong data-start=\"183\" data-end=\"228\"\u003eKeep supply and return vents unobstructed\u003c\/strong\u003e for even heating and cooling.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rc6y9d\" data-start=\"261\" data-end=\"344\"\u003e\n\u003cp data-start=\"263\" data-end=\"344\"\u003e\u003cstrong data-start=\"263\" data-end=\"292\"\u003eCheck thermostat settings\u003c\/strong\u003e to ensure proper operation of the furnace and AC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1pa5lbv\" data-start=\"345\" data-end=\"413\"\u003e\n\u003cp data-start=\"347\" data-end=\"413\"\u003e\u003cstrong data-start=\"347\" data-end=\"391\"\u003eInspect refrigerant lines and insulation\u003c\/strong\u003e for wear or damage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ymh11t\" data-start=\"414\" data-end=\"494\"\u003e\n\u003cp data-start=\"416\" data-end=\"494\"\u003e\u003cstrong data-start=\"416\" data-end=\"454\"\u003eKeep the furnace and AC area clean\u003c\/strong\u003e to ensure safe operation and airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"10a9hlq\" data-start=\"495\" data-end=\"588\"\u003e\n\u003cp data-start=\"497\" data-end=\"588\"\u003e\u003cstrong data-start=\"497\" data-end=\"538\"\u003eRinse AC condenser coils periodically\u003c\/strong\u003e to remove dust buildup and maintain efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12w8qvi\" data-start=\"589\" data-end=\"718\" data-is-last-node=\"\"\u003e\n\u003cp data-start=\"591\" data-end=\"718\" data-is-last-node=\"\"\u003e\u003cstrong data-start=\"591\" data-end=\"635\"\u003eSchedule annual professional maintenance\u003c\/strong\u003e to inspect burners, heat exchanger, refrigerant levels, and electrical components.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/article\u003e\n\u003c\/div\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":46812772499593,"sku":"GLXS5BA2410 \/ CAPTA3022A3 \/ GR9T800603AN","price":4578.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0759\/2443\/9177\/files\/stdcond-captacoil-80_upflowfurn.webp?v=1779806305","url":"https:\/\/mobility-ready.com\/products\/goodman-2-ton-60-000-btu-80-afue-gas-furnace-and-air-conditioner-system-upflow-14-5-seer2-r32-2","provider":"Supplies for Happy Tails","version":"1.0","type":"link"}