{"product_id":"goodman-5-ton-24-5-width-upflow-downflow-cased-evaporator-coil-txv-r32","title":"Goodman - 5 Ton - 24.5\" Width Upflow\/Downflow Cased Evaporator Coil TXV - R32 - CAPTA6030D3","description":"\u003ch2\u003e\u003cspan\u003eGoodman - 5 Ton - 24.5\" Width Upflow\/Downflow Cased Evaporator Coil TXV - R32 - CAPTA6030D3\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eAn AC or heat pump system is only as good as its evaporator coil. The Goodman CAPTA evaporator coils are designed with this simple thought in mind for its longevity, accessibility, and value as their other heating and cooling equipment. The advanced design and all-aluminum constriction of this coil improves its durability and heat transfer efficiency. The CAPTA series are cased A-Coils for use in Upflow\/Downflow applications. These units include an internal TXV (thermostatic expansion valve), which is perfect for high-performance systems. Goodman pressure tests each coil twice prior to it leaving the factory. Whether you are replacing an old failing coil or installing a new system, you can choose Goodman's CAPTA units with confidence.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cspan\u003eFeatures\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAll-Aluminum Coil: Goodman's evaporator coils maximize surface area and optimize heat transfer for efficient comfort by using a reliable all-aluminum design complete with sine fins and grooved tubes.\u003c\/li\u003e\n\u003cli\u003eInternal Thermostatic Expansion Valve: Goodman's CAPTA units have a factory-installed internal thermostatic expansion valve, which streamlines installation and maintains ideal refrigerant flow for your system.\u003c\/li\u003e\n\u003cli\u003eCabinet Durability: Providing superior longevity and efficiency, CAPTA units have a galvanized, embossed, and insulated cabinet that protects the coil and prevents air leakage.\u003c\/li\u003e\n\u003cli\u003eCondensate Management: Keeping your system sage and operational, the CAPTA units feature a foil-faced insulation to inhibit the formation of condensate and a rust-resistant, DecaBDE-free thermoplastic drain pan secondary drain connections. The drain pan is UV-resistant.\u003c\/li\u003e\n\u003cli\u003eR32 Compatibility: Complies with Clean Air Act New Refrigerant Requirements.\u003c\/li\u003e\n\u003cli\u003e10-Year Limited Warranty\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eSpecifications\u003c\/h5\u003e\n\u003cstyle type=\"text\/css\"\u003e\n.tg  {border-collapse:collapse;border-spacing:0;}\n.tg td{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg th{border-color:black;border-style:solid;border-width:1px;font-family:Arial, sans-serif;font-size:14px;\n  font-weight:normal;overflow:hidden;padding:10px 5px;word-break:normal;}\n.tg .tg-cly1{text-align:left;vertical-align:middle}\n.tg .tg-wa1i{font-weight:bold;text-align:center;vertical-align:middle}\n\u003c\/style\u003e\n\u003ctable class=\"tg\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"tg-wa1i\"\u003eSKU\u003c\/th\u003e\n\u003cth class=\"tg-cly1\"\u003eCAPTA6030D3\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWeight (in lbs)\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e70.000000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eBrand\/Manufacturer\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eGoodman\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eConfiguration\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eUpflow \/ Downflow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eRefrigerant\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eR32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eLiquid Line\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eSuction Line\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e7\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eTonnage\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e5 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eStyle\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eA-Coil\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eCertification\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003eETL Listed, AHRI Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eHeight\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e30\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eWidth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e24.5\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"tg-wa1i\"\u003eDepth\u003c\/td\u003e\n\u003ctd class=\"tg-cly1\"\u003e21\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cspan style=\"font-size: 0.875rem;\"\u003eManual\u003c\/span\u003e\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman_Vertical_Coil_Install_Manual_v3.2023.pdf?v=1725699589\" target=\"_blank\"\u003e\u003cstrong\u003eInstallation Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: bold;\"\u003e\u003ca rel=\"noopener\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0794\/3104\/1346\/files\/Goodman-CAPTA32-coil_Spec_Shet.pdf?v=1725699589\" target=\"_blank\"\u003e\u003cstrong\u003eSpec Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003eWhat our Experts Think\u003c\/h5\u003e\n\u003cul data-start=\"102\" data-end=\"657\"\u003e\n\u003cli data-section-id=\"1qgredv\" data-start=\"102\" data-end=\"196\"\u003e\n\u003cp data-start=\"104\" data-end=\"196\"\u003e\u003cstrong data-start=\"104\" data-end=\"122\"\u003eHigh Capacity:\u003c\/strong\u003e 5 Ton coil designed for larger residential or light commercial systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"671k6h\" data-start=\"197\" data-end=\"289\"\u003e\n\u003cp data-start=\"199\" data-end=\"289\"\u003e\u003cstrong data-start=\"199\" data-end=\"225\"\u003eFlexible Installation:\u003c\/strong\u003e 24.5\" width supports upflow or downflow cased configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"69rscq\" data-start=\"290\" data-end=\"387\"\u003e\n\u003cp data-start=\"292\" data-end=\"387\"\u003e\u003cstrong data-start=\"292\" data-end=\"312\"\u003ePrecise Cooling:\u003c\/strong\u003e TXV (Thermostatic Expansion Valve) ensures accurate refrigerant control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"126ra6k\" data-start=\"388\" data-end=\"475\"\u003e\n\u003cp data-start=\"390\" data-end=\"475\"\u003e\u003cstrong data-start=\"390\" data-end=\"419\"\u003eEco-Friendly Refrigerant:\u003c\/strong\u003e Compatible with R32 for reduced environmental impact.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"pd0ozp\" data-start=\"476\" data-end=\"565\"\u003e\n\u003cp data-start=\"478\" data-end=\"565\"\u003e\u003cstrong data-start=\"478\" data-end=\"497\"\u003eDurable Design:\u003c\/strong\u003e Built to withstand long-term use and varied operating conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1rlfaho\" data-start=\"566\" data-end=\"657\"\u003e\n\u003cp data-start=\"568\" data-end=\"657\"\u003e\u003cstrong data-start=\"568\" data-end=\"592\"\u003eOptimal Performance:\u003c\/strong\u003e Engineered for efficient heat exchange and consistent airflow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003eQ\u0026amp;A\u003c\/h5\u003e\n\u003cp data-start=\"111\" data-end=\"336\"\u003e\u003cstrong data-start=\"111\" data-end=\"139\"\u003eQ: What is this product?\u003c\/strong\u003e\u003cbr data-start=\"139\" data-end=\"142\"\u003eA: This is a \u003cstrong data-start=\"155\" data-end=\"193\"\u003e5 ton cased indoor evaporator coil\u003c\/strong\u003e designed for split central air conditioners and heat pumps – part of the Goodman HVAC system components. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"338\" data-end=\"577\"\u003e\u003cstrong data-start=\"338\" data-end=\"405\"\u003eQ: What configuration and installation options does it support?\u003c\/strong\u003e\u003cbr data-start=\"405\" data-end=\"408\"\u003eA: It supports \u003cstrong data-start=\"423\" data-end=\"446\"\u003eUpflow and Downflow\u003c\/strong\u003e airflow configurations, offering flexible placement in attics, closets, or mechanical rooms. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"579\" data-end=\"821\"\u003e\u003cstrong data-start=\"579\" data-end=\"635\"\u003eQ: What refrigerant and metering device does it use?\u003c\/strong\u003e\u003cbr data-start=\"635\" data-end=\"638\"\u003eA: Made for \u003cstrong data-start=\"650\" data-end=\"670\"\u003eR‑32 refrigerant\u003c\/strong\u003e with a \u003cstrong data-start=\"678\" data-end=\"729\"\u003efactory‑installed Thermal Expansion Valve (TXV)\u003c\/strong\u003e for precise refrigerant flow and improved efficiency. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"823\" data-end=\"1125\"\u003e\u003cstrong data-start=\"823\" data-end=\"870\"\u003eQ: What are its core construction features?\u003c\/strong\u003e\u003cbr data-start=\"870\" data-end=\"873\"\u003eA: It has an \u003cstrong data-start=\"886\" data-end=\"918\"\u003eall‑aluminum evaporator coil\u003c\/strong\u003e, \u003cstrong data-start=\"920\" data-end=\"954\"\u003egalvanized steel cased cabinet\u003c\/strong\u003e, \u003cstrong data-start=\"956\" data-end=\"981\"\u003efoil‑faced insulation\u003c\/strong\u003e to reduce condensation, and \u003cstrong data-start=\"1010\" data-end=\"1053\"\u003erust‑resistant thermoplastic drain pans\u003c\/strong\u003e with secondary drain connections. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1127\" data-end=\"1307\"\u003e\u003cstrong data-start=\"1127\" data-end=\"1158\"\u003eQ: What are the dimensions?\u003c\/strong\u003e\u003cbr data-start=\"1158\" data-end=\"1161\"\u003eA: The coil measures approximately \u003cstrong data-start=\"1196\" data-end=\"1232\"\u003e24.5″ wide × 21″ deep × 30″ high\u003c\/strong\u003e — a standard 5‑ton indoor coil size. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1309\" data-end=\"1501\"\u003e\u003cstrong data-start=\"1309\" data-end=\"1354\"\u003eQ: What line sizes are used on this coil?\u003c\/strong\u003e\u003cbr data-start=\"1354\" data-end=\"1357\"\u003eA: The \u003cstrong data-start=\"1364\" data-end=\"1401\"\u003eliquid line service valve is 3\/8″\u003c\/strong\u003e and the \u003cstrong data-start=\"1410\" data-end=\"1435\"\u003esuction valve is 7\/8″\u003c\/strong\u003e, typical for 5‑ton systems. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1503\" data-end=\"1673\"\u003e\u003cstrong data-start=\"1503\" data-end=\"1533\"\u003eQ: Is this coil certified?\u003c\/strong\u003e\u003cbr data-start=\"1533\" data-end=\"1536\"\u003eA: Yes — it’s \u003cstrong data-start=\"1550\" data-end=\"1583\"\u003eAHRI certified and ETL listed\u003c\/strong\u003e, ensuring tested performance and safety compliance. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1675\" data-end=\"1858\"\u003e\u003cstrong data-start=\"1675\" data-end=\"1721\"\u003eQ: What warranty coverage does it include?\u003c\/strong\u003e\u003cbr data-start=\"1721\" data-end=\"1724\"\u003eA: Goodman generally offers a \u003cstrong data-start=\"1754\" data-end=\"1788\"\u003e10‑year parts limited warranty\u003c\/strong\u003e on cased coils when registered. \u003cspan class=\"\" data-state=\"closed\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"1860\" data-end=\"2168\"\u003e\u003cstrong data-start=\"1860\" data-end=\"1911\"\u003eQ: What are the benefits of the TXV and design?\u003c\/strong\u003e\u003cbr data-start=\"1911\" data-end=\"1914\"\u003eA: The \u003cstrong data-start=\"1921\" data-end=\"1965\"\u003eTXV helps regulate refrigerant precisely\u003c\/strong\u003e for better cooling performance and improved system efficiency, while the \u003cstrong data-start=\"2039\" data-end=\"2071\"\u003ecased cabinet and insulation\u003c\/strong\u003e help reduce condensation issues and simplify installation.\u003c\/p\u003e\n\u003ch5 style=\"font-weight: bold;\"\u003eMaintenance Tips\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli data-section-id=\"iph6c8\" data-start=\"103\" data-end=\"203\"\u003e\n\u003cp data-start=\"105\" data-end=\"203\"\u003e\u003cstrong data-start=\"105\" data-end=\"158\"\u003eCheck and replace the air filter every 1–3 months\u003c\/strong\u003e to maintain airflow and system efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"o0iiq8\" data-start=\"204\" data-end=\"293\"\u003e\n\u003cp data-start=\"206\" data-end=\"293\"\u003eKeep the \u003cstrong data-start=\"215\" data-end=\"256\"\u003earea around the evaporator coil clear\u003c\/strong\u003e of dust, debris, and obstructions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1a0mxs2\" data-start=\"294\" data-end=\"408\"\u003e\n\u003cp data-start=\"296\" data-end=\"408\"\u003eInspect \u003cstrong data-start=\"304\" data-end=\"330\"\u003ecoil fins and surfaces\u003c\/strong\u003e periodically; gently clean to prevent dirt buildup that reduces efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12atwg5\" data-start=\"409\" data-end=\"503\"\u003e\n\u003cp data-start=\"411\" data-end=\"503\"\u003eEnsure \u003cstrong data-start=\"418\" data-end=\"457\"\u003edrain pan and condensate drain line\u003c\/strong\u003e are clear to prevent water damage or clogs.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"12l7k8q\" data-start=\"504\" data-end=\"577\"\u003e\n\u003cp data-start=\"506\" data-end=\"577\"\u003eVerify \u003cstrong data-start=\"513\" data-end=\"549\"\u003erefrigerant lines and insulation\u003c\/strong\u003e are intact and undamaged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"6o0rvw\" data-start=\"578\" data-end=\"665\"\u003e\n\u003cp data-start=\"580\" data-end=\"665\"\u003eCheck \u003cstrong data-start=\"586\" data-end=\"634\"\u003eTXV (Thermostatic Expansion Valve) operation\u003c\/strong\u003e for proper refrigerant flow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1ujoaa9\" data-start=\"666\" data-end=\"759\"\u003e\n\u003cp data-start=\"668\" data-end=\"759\"\u003eMaintain \u003cstrong data-start=\"677\" data-end=\"718\"\u003e2–3 feet of clearance around the unit\u003c\/strong\u003e for proper airflow and service access.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"1y520tg\" data-start=\"760\" data-end=\"858\"\u003e\n\u003cp data-start=\"762\" data-end=\"858\"\u003eListen for \u003cstrong data-start=\"773\" data-end=\"791\"\u003eunusual noises\u003c\/strong\u003e such as rattling or hissing that may indicate mechanical issues.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"g169vb\" data-start=\"859\" data-end=\"933\"\u003e\n\u003cp data-start=\"861\" data-end=\"933\"\u003eEnsure \u003cstrong data-start=\"868\" data-end=\"906\"\u003ethermostat is functioning properly\u003c\/strong\u003e and properly calibrated.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-section-id=\"q9tku6\" data-start=\"934\" data-end=\"1058\" data-is-last-node=\"\"\u003e\n\u003cp data-start=\"936\" data-end=\"1058\" data-is-last-node=\"\"\u003eSchedule \u003cstrong data-start=\"945\" data-end=\"984\"\u003eannual professional HVAC inspection\u003c\/strong\u003e to clean coils, check refrigerant, and verify overall system performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Goodman","offers":[{"title":"Default Title","offer_id":46812793798793,"sku":"CAPTA6030D3","price":717.81,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0759\/2443\/9177\/files\/download_5_c8c09b5c-38f0-40b7-b983-69a5ebb5d5a5.webp?v=1779806661","url":"https:\/\/mobility-ready.com\/products\/goodman-5-ton-24-5-width-upflow-downflow-cased-evaporator-coil-txv-r32","provider":"Supplies for Happy Tails","version":"1.0","type":"link"}