Features
  • Ideal size to cover a medium-sized house
  • 1.5 ton, 13.4 SEER2 AC-only condenser
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Low sound output
  • Fully charged for up to 15' of line set
  • Factory-installed filter drier
  • 1.5 ton horizontal evaporator coil
  • Can be used with heat pump and AC-only condensers
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Galvanized, embossed, and insulated coil cabinet to protect the coil and prevent air leakage
  • Factory-installed TXV kit
  • This furnace is ideal to heat a medium-sized house (in average climate conditions)
  • 60,000 BTU 96% AFUE two stage variable speed natural gas furnace
  • Requires plastic/PVC flue venting
  • Can be used in the downflow or horizontal orientation
  • Can be converted to propane with an LP conversion kit (sold separately)
  • Innovative design for electrical efficiency, safety, and lower sound output
Specifications
SKU GLXS3BN1810
Weight 130.000000
Manufacturer Goodman
Replaces Add GSX130181 and GSXN3N1810
Product Features New Refrigerant Compliant
Cooling BTU 18,000
Decibel Level (dBA) 73
Horsepower 1/8 HP
Refrigerant R32
SEER2 13.4
Condenser Stages Single Stage
Compressor Type Rotary
Liquid Line 3/8"
Suction Line 3/4"
Liquid Valve Size 3/8"
Suction Valve Size 3/4"
Electrical 208 / 230 V. 1 Phase 60 Hz
Max Breaker Size 15 Amps
Min. Breaker Size 10.9 Amps
Tonnage 1.5 Ton
Connection Sweat
Height 27 1/2"
Width 26"
Depth 26"
Owner's Manual
What our Experts Think
  • Right‑sized comfort for smaller homes: This 1.5‑ton system blends a 13.4 SEER2 R‑32 air conditioner with a 60,000 BTU 96% AFUE gas furnace, making it a good fit for small to medium homes where balanced heating and cooling matters.

  • Superior heating efficiency: With 96% AFUE, nearly all the fuel is converted into usable heat, which trims energy waste and lowers winter heating costs compared with standard 80% furnaces.

  • Solid cooling performance: The GLXS3BN1810 condenser uses R‑32 refrigerant and delivers dependable cooling at 13.4 SEER2, striking a practical balance of efficiency and upfront cost.

  • Modern furnace features: The GMVC960603BN furnace incorporates a variable‑speed ECM blower and two‑stage gas valve, which smooths airflow and enhances comfort consistency across seasons.

  • TXV‑equipped evaporator coil: The included CHPTA1822B3 coil with a TXV regulates refrigerant flow more precisely, boosting performance and humidity control.

  • Flexible installation: Horizontal or multi‑position design fits attic, crawlspace, or tight utility locations, aiding versatile system placement.

  • Long‑term confidence: Standard 10‑year parts warranty + lifetime heat exchanger coverage (with registration) offers peace of mind and supports lower long‑term ownership costs.

  • Strong value choice: Experts see this as a high‑efficiency, budget‑friendly HVAC package delivering solid performance and modern refrigerant tech without the premium cost of ultra‑high SEER systems.


Q&A

Q: What type of HVAC system is this?
A: This is a complete Goodman high-efficiency central heating and cooling system that includes a 1.5‑ton air conditioner (GLXS3BN1810), 60,000 BTU 96% AFUE gas furnace (GCVC960603BN), and CHPTA1822B3 cased evaporator coil, providing year‑round comfort.

Q: What size home is a 1.5‑ton system suitable for?
A: A 1.5‑ton AC (18,000 BTU) system is ideal for small homes or apartments around 600–1,000 sq. ft., depending on insulation, climate, and layout.

Q: How energy efficient is this Goodman system?
A: The system delivers 13.4 SEER2 cooling efficiency and a 96% AFUE gas furnace, meaning nearly all fuel is converted into usable heat, offering high-efficiency heating and cooling.

Q: What refrigerant does the AC use?
A: The condenser uses R‑32 refrigerant, a modern, eco-friendly refrigerant designed for higher energy efficiency and lower environmental impact.

Q: Does the furnace include advanced technology?
A: Yes. The GCVC960603BN furnace features a variable-speed ECM blower motor and high-efficiency design for quieter operation, consistent airflow, and precise temperature control.

Q: Can this system be installed horizontally?
A: Yes. Both the furnace and coil support horizontal airflow installation, making it suitable for attics, crawl spaces, or closets where horizontal placement is required.

Q: What components are included in this system?
A: The package includes:

  • GLXS3BN1810 – 1.5 Ton 13.4 SEER2 outdoor AC condenser

  • CHPTA1822B3 – 60,000 BTU cased evaporator coil

  • GCVC960603BN – 96% AFUE gas furnace


Maintenance Tips
  • Replace air filters every 1–3 months: Clean filters prevent dust buildup, maintain airflow, and protect the ECM blower motor.

  • Keep the outdoor condenser clear: Remove leaves, debris, and maintain 2–3 ft clearance for optimal cooling and energy efficiency.

  • Inspect and clean the evaporator coil and drain pan: The CHPTA aluminum coil should be checked for dirt or clogs to avoid water leaks or reduced efficiency. (hvacdirect.com)

  • Check refrigerant line insulation: Ensure suction line insulation is intact to maintain system efficiency.

  • Inspect vents and airflow: Keep supply and return vents clear of furniture or dust for balanced air distribution.

  • Annual professional service: Have a certified HVAC technician inspect the furnace heat exchanger, blower motor, refrigerant levels, and safety controls yearly.

  • Maintain a clean furnace area: Clear surrounding space for proper airflow and safe operation of the 96% AFUE gas furnace. (thefurnaceoutlet.c