The Goodman GLZS4BA3010 heat pump condenser is a standard efficiency, low-cost solution for an all-electric home when paired with a suitable heat pump coil or air handler. Just like all of Goodman's equipment, the GLZS4BA3010 is manufactured with high-quality materials to provide a superior comfort in your home.
Please note this is an outdoor unit only, for full system operation this needs to be paired with an indoor unit.
| 2.5 Ton 14.3 SEER2 Goodman Heat Pump - R32 | |
|---|---|
| SKU | GLZS4BA3010 |
| Weight (in lbs) | 190.000000 |
| Brand/Manufacturer | Goodman |
| Replaces | GSZ140301, GSZB403010 |
| HSPF2 | 7.8 |
| Cooling BTU | 30,000 |
| Heating BTU | 30,000 |
| Blower Motor | Single Speed PSC Motor |
| Decibel Level (dBA) | 77 |
| Horsepower | 1/6 HP |
| Refrigerant | R32 |
| SEER2 (Efficiency) | 14.3 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Electrical | 208/230v 1 Phase 60 Hz |
| Max Breaker Size | 25 Amps |
| Min. Breaker Size | 15.0 Amps |
| Tonnage | 2.5 Ton |
| Connection | Sweat |
| Height | 39 1/2" |
| Width | 29" |
| Depth | 29" |
Balanced Seasonal Comfort with R‑32 Refrigerant
The Goodman GLZS4BA3010 2.5 Ton Heat Pump Condenser delivers 30,000 BTU cooling and heating capacity with 14.3 SEER2 and ~7.8 HSPF2 efficiency, offering reliable year‑round comfort and modern R‑32 refrigerant compliance for lower environmental impact.
Single‑Stage Reliability
Its single‑stage rotary compressor provides consistent performance and straightforward operation—ideal for homeowners who want dependable heating & cooling without complexity.
Quiet & Weather‑Ready Outdoor Build
With a 77 dB sound level, heavy‑gauge galvanized‑steel cabinet and removable grille design, the unit is built to withstand outdoor conditions while minimizing noise and corrosion.
SmartShift® Defrost & Protective Features
SmartShift® technology ensures quiet, reliable defrost cycles in heat mode, while factory‑installed components like high‑capacity muffler, accumulator, and filter drier protect the system and enhance durability.
Installer‑Friendly Connections
Service valves with easy access to gauge ports, sweat connections, and fully‑enclosed contactor with lug connection help HVAC pros complete installations and maintenance more efficiently.
Q1: What type of HVAC unit is this?
A: The Goodman GLZS4BA3010 is a 2.5 ton heat pump condenser designed for year‑round heating and cooling in split‑system installations. It must be paired with a compatible indoor coil or air handler.
Q2: What efficiency ratings does it have?
A: It delivers 14.3 SEER2 cooling efficiency and ~7.8 HSPF2 heating performance, offering balanced comfort and energy savings.
Q3: Which refrigerant does this heat pump use?
A: This model uses R‑32 refrigerant, a modern, lower‑environmental‑impact refrigerant with improved energy performance.
Q4: What kind of compressor and operation does the unit use?
A: It features a single‑stage rotary compressor with a single‑speed PSC condenser fan motor for reliable, consistent operation.
Q5: What key protective features are included?
A: The unit includes factory‑installed filter drier, suction‑line accumulator, crankcase heater, high‑capacity muffler, and high/low‑pressure switches to help improve durability and performance.
Q6: What cabinet and build features does it have?
A: Built with a heavy‑gauge galvanized‑steel cabinet, removable grille top, and steel louver coil guard with a durable architectural gray finish — rated to resist corrosion and meet structural wind requirements when anchored.
Q7: What are typical dimensions and sound levels?
A: Approximate size is 29" W × 29" D × 39.5" H, with typical sound levels around 77 dBA during operation.
Keep Outdoor Coil Clean – Regularly remove leaves, grass, and dirt from the condenser fins and wash gently with a hose (inside‑out) to maintain efficiency; avoid pressure washers that can bend fins.
Maintain Proper Airflow Around Unit – Ensure at least ~18–24″ clearance at sides and ~36″ in front so airflow isn’t restricted.
Check Electrical Connections Annually – Inspect contactor, capacitor and wiring for loose or corroded connections that can reduce performance or cause failures.
Clear Drainage and Pad Area – Make sure the unit base is level and that water drains away from the pad to avoid corrosion and flooding around the condenser.
Inspect Refrigerant Lines – Ensure R32 refrigerant lines are properly insulated and leak‑free; low charge reduces heating/cooling effectiveness.
Annual HVAC Professional Service – Have a licensed technician check refrigerant levels, clean coils, test defrost operation, and verify the heat pump’s SEER2 performance