Goodman - 2 Ton/24,000 BTU Air Conditioner Condenser - SEER2 15.2 - Single Stage - R32 - GLXS5BA2410
The Goodman 2 Ton 15.2 SEER2 Air Conditioner Condenser (R-32) - GLXS5BA2410 uses the environmentally friendly refrigerant R-32 and features the unique Goodman sound control top design for quiet operation. In addition, the unit has an attractive louvered metal guard that protects the coil from damage plus a powder-paint finish that provides premium durability and improved UV protection.
Features
- Energy-efficient compressor
- Fully charged for 15' of tubing length
- Copper tube/ enhanced aluminum fin coil-5mm diameter
- Factory-installed filter drier
- Sweat connection service valves with easy access to gauge ports
- Enclosed contactor
- High-pressure switch
- Ground lug connection
- Capacitors with extended life
- AHRI Certified
- ETL Listed
Specifications
| Model Number(s) |
GLXS5BA2410 |
| Brand |
Goodman |
| Type |
Air Conditioning |
| Category |
Condensers |
| Ton |
2.0 Ton |
| SEER |
15.2 |
| Cooling Stage(s) |
1 |
| Compressor Stage |
Single |
| Voltage |
208/230V |
| Refrigerant Type |
R-32 |
Manual
What our Experts Think
-
High Efficiency: SEER2 15.2 reduces energy consumption while maintaining strong cooling.
-
Optimal Cooling: 2 Ton / 24,000 BTU capacity suits medium-sized homes or spaces.
-
Reliable Operation: Single-stage compressor provides consistent, dependable cooling.
-
Eco-Friendly Refrigerant: R32 minimizes environmental impact compared to older refrigerants.
-
Compact Design: Fits most standard condenser locations for easy installation.
-
Quiet Performance: Engineered for low operational noise.
-
Durable Build: Built to last in diverse climates with long-term reliability.
Q&A
Q: What cooling capacity does this condenser provide?
A: This unit delivers 24,000 BTU (2 tons) of cooling capacity, suitable for smaller to medium homes and residential cooling needs when matched with a compatible indoor coil or air handler.
Q: How energy efficient is this model?
A: It’s rated 15.2 SEER2, providing higher energy efficiency and potential lower utility costs compared with standard SEER units.
Q: What type of refrigerant does it use?
A: Uses R‑32 refrigerant, a more environmentally responsible option with lower global warming potential (GWP).
Q: What compressor and operation does it have?
A: Equipped with a single‑stage scroll compressor for dependable, consistent cooling performance.
Q: What are the electrical requirements?
A: Operates on 208/230 V single‑phase, 60 Hz power, typical for residential condensers.
Q: What are the line and connection sizes?
A: Liquid line is 3/8″ and suction line is 3/4″, with sweat connections and easy‑access service valves.
Q: How quiet is the unit during operation?
A: Runs around 69–73 dBA, which is typical for outdoor AC condensers and designed for quieter operation.
Q: What durability features does it include?
A: Features a galvanized, powder‑coated steel cabinet, steel louver coil guard, and factory‑installed filter drier for weather resistance and protection.
Maintenance Tips
-
Clean the outdoor condenser coil regularly to remove dirt, leaves, and debris for optimal efficiency.
-
Maintain 2–3 feet of clearance around the unit to ensure proper airflow.
-
Replace or clean indoor air filters every 1–3 months to maintain airflow and cooling performance.
-
Inspect refrigerant lines and insulation for damage or wear.
-
Keep the condenser fan and top grille clear of debris to prevent airflow restriction.
-
Check the condensate drain line periodically to prevent clogs and water buildup.
-
Ensure thermostat is functioning properly and set for efficient cooling cycles.
-
Listen for unusual noises such as rattling or buzzing, which may indicate mechanical issues.
-
After storms or strong winds, inspect the outdoor unit for debris or damage.
-
Schedule annual professional HVAC maintenance to inspect refrigerant levels, electrical components, and overall system performance.