The Goodman GPUM32404031 is a gas heat and electric AC packaged unit, ready for any application where it is not convenient to have an indoor furnace or air handler. At 13.4 SEER2 and 81% AFUE, the GPUM32404031 is an inexpensive option with a standard efficiency designed for rooftop and next-to-building applications.
| 2 Ton 40,000 BTU 13.4 SEER2 Goodman Ultra-Low NOx Gas Packaged Unit - R32 | |
|---|---|
| SKU | GPUM32404031 |
| Weight (in lbs) | 435.000000 |
| AHRI Certificate Number | 209319523 |
| Brand/Manufacturer | Goodman |
| Replaces | GPG1424040M41 |
| Product Features | Ultra-Low NOx |
| Furnace Efficiency / AFUE | 80% |
| Cooling BTU | 23,000 BTU |
| Heating BTU | 40,000 BTU |
| Blower Motor | Multi-Speed |
| Maximum CFM | 800 |
| Decibel Level (dBA) | 78 decibels |
| Configuration | Downflow/Horizontal |
| Refrigerant | R32 |
| SEER2 (Efficiency) | 13.4 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Electrical | 208/230v 1 Phase 60 Hz |
| Max Breaker Size | 35 Amps |
| Min. Breaker Size | 21.6 Amps |
| Tonnage | 2 Ton |
| Low NOx | Ultra Low NOx |
| Fuel Type | Natural Gas |
| Height | 34 3/4" |
| Width | 47" |
| Depth | 51" |
Compact All‑In‑One Comfort: The Goodman GPUM32404031 Packaged Unit combines gas heating and electric cooling in a single packaged system, eliminating the need for a separate furnace or air handler — perfect for tight rooftops, next‑to‑building installs, or homes without indoor HVAC space.
Cleaner Combustion (Ultra‑Low NOx): Designed to meet Ultra‑Low NOx emission standards, it’s a great choice for regions with strict air‑quality regulations while reducing environmental impact compared with standard models.
Balanced Year‑Round Performance: With 13.4 SEER2 cooling and ≈81% AFUE heating, this unit delivers a solid mix of energy‑efficient air conditioning and dependable gas heat for everyday use.
Flexible Installation: The downflow or horizontal discharge design allows installers to fit the unit in varied ductwork layouts and mechanical spaces without extra components.
R32 Refrigerant & Quiet Operation: Uses R32 refrigerant for effective heat transfer with lower environmental impact, and the design includes a multi‑speed blower and scroll compressor for quieter, consistent performance.
Durable Build & Warranty Support: Built with a heavy‑gauge, insulated cabinet and corrosion‑resistant coils, and backed by Goodman’s long‑term parts and heat exchanger warranty when registered.
Value‑Driven Choice: This unit offers practical efficiency, environmental compliance, and simplified installation, making it a smart packaged HVAC solution for homeowners, modular homes, and light commercial applications.
Q: What kind of HVAC unit is this?
A: It’s an all‑in‑one packaged gas‑electric comfort unit combining heating and cooling in a single outdoor cabinet, ideal where indoor furnaces or air handlers aren’t practical.
Q: What cooling and heating capacities does it offer?
A: Provides about 2 tons (~23,000 BTU) of cooling at 13.4 SEER2 and 40,000 BTU of gas heat, offering balanced year‑round comfort.
Q: What does 13.4 SEER2 mean?
A: SEER2 14.3 measures seasonal cooling efficiency under updated test standards — higher SEER2 helps reduce electric cooling costs versus low‑efficiency units.
Q: What does Ultra‑Low NOx mean?
A: “Ultra‑Low NOx” refers to reduced nitrogen oxide emissions to meet stricter air quality standards in many regions.
Q: What refrigerant and electrical specs does it use?
A: Uses R32 refrigerant (more efficient and lower‑impact than older types) and runs on 208/230 V single‑phase power standard for packaged HVAC units.
Q: What type of compressor and blower does it have?
A: Features a single‑stage scroll compressor for dependable cooling and a multi‑speed ECM blower for smooth airflow and quieter operation.
Q: What installation configurations are supported?
A: Designed for downflow or horizontal airflow positions — flexible for roof‑mounts, slab installs, or tight mechanical spaces.
Replace Air Filters Regularly: Inspect monthly and replace every 1–3 months to maintain airflow and protect the blower and coil.
Keep Vents & Registers Clear: Ensure supply and return vents are unobstructed for even heating and cooling.
Inspect Gas & Venting System: Check gas connections, burners, and venting for blockages or leaks to ensure safe operation.
Clean Around the Unit: Remove dust, debris, and vegetation around the packaged unit for proper airflow.
Check Electrical Connections: Inspect 230V wiring, disconnects, and capacitors for secure and corrosion-free operation.
Monitor System Performance: Listen for unusual noises; check heating and cooling output for efficiency.
Schedule Annual Professional Service: A licensed HVAC technician should inspect burners, heat exchanger, gas pressure, refrigerant charge, fan motor, and safety controls yearly.