Only a few left—secure yours before it’s gone for good!
Your items are reserved, but only for a limited time!
Grab it now at a discounted price before the deal ends!
$1,899.97 USD
$2,499.97 USD
$41,649.00 USD
$44,099.00 USD
$5,499.00 USD
$1,699.97 USD
$1,799.00 USD
$2,498.00 USD
$2,799.98 USD
$3,099.00 USD
$4,398.00 USD
$1,499.00 USD
A Goodman gas furnace and air conditioner system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman gas furnace and air conditioner system is the perfect choice for all of your heating and cooling needs.
| 2 Ton 13.4 SEER2 Goodman Air Conditioner Condenser - R32 | |
|---|---|
| SKU | GLXS3BN2410 |
| Weight | 130.000000 |
| Manufacturer | Goodman |
| Replaces | GSX130241 and GSXN3N2410 |
| Product Features | New Refrigerant Compliant |
| Cooling BTU | 24,000 |
| Decibel Level (dBA) | 74 |
| Horsepower | 1/8 HP |
| Refrigerant | R32 |
| SEER2 | 13.4 |
| Condenser Stages | Single Stage |
| Compressor Type | Rotary |
| Liquid Line | 3/8" |
| Suction Line | 3/4" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 3/4" |
| Electrical | 208 / 230 V. 1 Phase 60 Hz |
| Max Breaker Size | 15 Amps |
| Min. Breaker Size | 10.9 Amps |
| Tonnage | 2 Ton |
| Connection | Sweat |
| Height | 27.5" |
| Width | 26" |
| Depth | 26" |
Year‑Round Comfort System: The Goodman CHPTA2426B3 HVAC System combines an 80% AFUE gas furnace with a 2 ton (60,000 BTU) air conditioner for reliable heating and cooling in one matched package.
Steady Heating Performance: 80% AFUE delivers consistent warmth and dependable operation, ideal for moderate‑climate homes.
Efficient Cooling: 14.3 SEER2 cooling helps reduce summer energy use while keeping indoor spaces comfortable.
Horizontal Installation Design: Suited for horizontal duct configurations, fitting crawlspaces, attics, or other low‑clearance areas with ease.
R32 Refrigerant Advantage: Uses R32 refrigerant for better heat transfer and a smaller environmental footprint than older refrigerants.
Coordinated System Efficiency: Engineered as a matched furnace + AC system to ensure balanced airflow, consistent capacity, and reliable seasonal performance.
Value‑Driven Comfort: Combines solid heating and cooling efficiency with installation flexibility, making it a practical, cost‑effective solution for whole‑home climate control.
Q: What’s included in this HVAC system?
A: This matched Goodman system includes a 2 ton R32 air conditioner condenser with 14.3 SEER2 cooling, a 60,000 BTU 80% AFUE gas furnace, and a horizontal cased evaporator coil (CHPTA2426B3) for efficient year‑round comfort.
Q: What cooling performance does this system offer?
A: The outdoor condenser delivers 2 tons of cooling (~24,000 BTU) with 14.3 SEER2 efficiency, helping reduce seasonal electricity use vs lower‑SEER systems.
Q: What does 80% AFUE mean for heating?
A: 80% AFUE means roughly 80 ¢ of every dollar spent on fuel becomes usable heat, offering standard heating efficiency with reliable performance.
Q: What refrigerant does this system use?
A: Uses R32 refrigerant, a modern refrigerant with better energy performance and lower environmental footprint than older alternatives.
Q: Is this system fit for horizontal installation?
A: Yes — the horizontal cased evaporator coil (CHPTA2426B3) and furnace support horizontal configuration, ideal for attics, closets, or crawlspaces with limited vertical space.
Q: What kind of blower and operation features are typical?
A: The furnace typically includes a multi‑speed ECM blower and single‑stage heating, offering smooth airflow and dependable performance.
Q: Why choose a matched HVAC system?
A: Matched components ensure optimized airflow, improved efficiency, balanced cooling/heating, and full warranty compatibility versus mismatched parts — boosting reliability and comfort.
Q: Who is this system best for?
A: Ideal for small to medium homes needing reliable, efficient year‑round cooling and standard‑efficiency heating with modern refrigerant compliance.
Replace Air Filters Regularly: Inspect monthly and replace every 1–3 months to maintain airflow and protect furnace and AC components.
Keep Vents & Registers Clear: Ensure supply and return vents are unobstructed for even heating and cooling.
Inspect Furnace Venting: Check intake and exhaust pipes for debris or blockages to maintain safe operation.
Clean Around the Units: Maintain 2–3 ft clearance around furnace and condenser to prevent dust buildup and allow proper airflow.
Check Thermostat & Electricals: Verify thermostat settings, gas supply, and 115V/208–230V circuits for correct operation.
Monitor System Performance: Listen for unusual noises from the blower or condenser; reduced heating or cooling efficiency may indicate maintenance needs.
Schedule Annual Professional Service: A licensed HVAC technician should inspect burners, heat exchanger, gas pressure, AC refrigerant charge, and safety controls yearly.