Only a few leftâsecure yours before itâs gone for good!
Your items are reserved, but only for a limited time!
Grab it now at a discounted price before the deal ends!
$1,899.97 USD
$2,499.97 USD
$41,649.00 USD
$44,099.00 USD
$5,499.00 USD
$1,699.97 USD
$1,799.00 USD
$2,498.00 USD
$2,799.98 USD
$3,099.00 USD
$4,398.00 USD
$1,499.00 USD
The AMST is all about effective air distribution. It includes an all-aluminum evaporator coil and internal factory-installed valves for cooling and heat pump applications thermal expansion. These advanced components excel at ensuring that your home stays comfortable and your central system runs efficiently. The ECM fan motor is a huge step up from older models as it requires less electricity to operate and provides more consistent air circulation.
| Model Number(s) | AMST42CU1300 |
|---|---|
| Brand | Goodman |
| Type | Air Conditioning |
| Category | Air Handlers |
| Ton | 3.5 Ton |
| Voltage | 208/230V |
| Refrigerant Type | R-32 |
| Height (Inches) | 53 7/16 |
| Width (Inches) | 21 |
| Depth (Inches) | 21 |
| UPC # | 633190042101 |
Modern Râ32 Ready Indoor Air Handler
The Goodman AMST42CU1300 3.5âŻTon Air Handler is built for Râ32 refrigerant split systems, providing improved environmental compliance and efficiency when paired with a matched outdoor unit.
Precise Cooling with FactoryâInstalled TXV
A builtâin thermostatic expansion valve (TXV) ensures accurate refrigerant metering and better coil performanceâhelping stabilize superheat, boost efficiency, and reduce loadârelated temperature swings.
EnergyâSmart ECM Blower Motor
The multiâspeed ECM blower adjusts airflow to match load demands, delivering quieter operation, smoother comfort, and lower electrical use compared with traditional PSC motors.
Flexible MultiâPosition Installation
Designed for upflow, downflow, and horizontal orientations, this air handler adapts to most duct layoutsâincluding attic, closet, or crawlspace installsâwithout complex cabinet modifications.
Durable, HighâPerformance Coil & Cabinet
The allâaluminum evaporator coil maximizes heat transfer and resists corrosion, while the SmartFrame cabinet delivers low air leakage and robust structural rigidity.
Condensation Control & Easy Maintenance
Features like a thermoplastic drain pan with secondary drains, foilâfaced insulation to reduce cabinet moisture, and toolâless filter access help prevent water issues and simplify servicing.
Q1: What type of HVAC component is this?
A: The Goodman AMST42CU1300 is a multiâposition indoor air handler designed for 3.5âŻton splitâsystem HVAC setups, providing conditioned air distribution and pairing with outdoor heat pumps or AC condensers.
Q2: What motor and airflow technology does it use?
A: It features a directâdrive, multiâspeed 9âspeed ECM blower motor, which delivers smooth, efficient airflow and quieter operation compared to singleâspeed motors.
Q3: Is a TXV included?
A: Yes â it includes factoryâinstalled thermal expansion valves (TXVs) for efficient refrigerant metering in both cooling and heat pump applications.
Q4: What refrigerant compatibility does it have?
A: This air handler is optimized for Râ32 refrigerant, supporting modern, environmentally friendly HVAC systems.
Q5: What installation orientations are supported?
A: The multiâposition design allows upflow, downflow, leftâhorizontal, or rightâhorizontal installation, offering flexible placement for various ductwork configurations.
Q6: What type of coil does it use?
A: It uses an allâaluminum evaporator (AlumaFin) coil for superior heat transfer and corrosion resistance.
Q7: What durability and build features does it offer?
A: The unit has a rigid SmartFrame cabinet with foilâfaced insulation, lowâleakage construction (<2% per ASHRAE standards), thermoplastic drain pan with secondary drains, and toolâless filter access for easy maintenance and reliable performance.
Replace or Clean the Air Filter Regularly â Check the indoor air filter every 1â3 months and replace or clean it to maintain proper airflow and keep the evaporator coil clean. A dirty filter restricts airflow and reduces efficiency.
Inspect & Clean the Evaporator Coil Annually â Dust and debris on the allâaluminum coil reduce heat transfer. Have a professional clean the coil each year to preserve comfort and efficiency.
Check Condensate Drain & Pan â Ensure the thermoplastic drain pan and condensate line are clear to prevent water buildup, microbial growth, and overflow issues.
Monitor Blower Motor Performance â The multiâspeed ECM motor delivers efficient airflow; annually inspect for proper operation and listen for unusual noises that could signal wear.
Verify Refrigerant Lines & TXV Operation â Make sure Râ32 refrigerant lines are leakâfree and insulated; the factoryâinstalled TXV should be checked during professional maintenance for correct metering.
Maintain Unit Clearance & Orientation â Keep surrounding area clear and ensure unit orientation (upflow/downflow/horizontal) is unobstructed so airflow isnât restricted.
Annual Professional HVAC Service â A licensed technician should inspect electrical connections, check refrigerant charge, clean coils, and test drain lines each year to maintain peak performance and system longevity.