Skip to product information
1 of 10

Goodman

Goodman - 3 Ton/36,000 BTU Air Conditioner Condenser - SEER2 14.3 - Single Stage - R32- GLXS4BA3610

Goodman - 3 Ton/36,000 BTU Air Conditioner Condenser - SEER2 14.3 - Single Stage - R32- GLXS4BA3610

1 Review

7% Sale

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price $2,456.70 Sale price $2,276.00
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$100.00

$30.00

$200.00

$70.00

Add-Ons Bundle

$100.00

$30.00

$200.00

$70.00

Bundle Offer

$300.00

$100.00

Recently Viewed

Goodman - 3 Ton/36,000 BTU Air Conditioner Condenser - SEER2 14.3 - Single Stage - R32- GLXS4BA3610

The Goodman brand has been focused on providing efficiency and comfort where it matters most while still being an inexpensive brand. With its superior components and a standard efficiency, the Goodman GLXS4BA3610 air conditioner condenser is a popular choice for homeowners around the United States.

Features
  • Ideal size to cover a small house in ideal climates
  • 3 ton, 14.3 SEER2 AC-only condenser
  • R32: Complies with Clean Air Act New Refrigerant Requirements
  • Fully charged for up to 15' of line set
  • Low sound output
  • Factory-installed filter drier
Specifications
3 Ton 14.3 SEER2 Goodman Air Conditioner Condenser - R32
SKU GLXS4BA3610
Weight (in lbs) 173.000000
Brand/Manufacturer Goodman
Replaces GSXN403610
Cooling BTU 36,000
Blower Motor Single Speed PSC Motor
Decibel Level (dBA) 67
Horsepower 1/6 HP
Refrigerant R32
SEER2 (Efficiency) 14.3
Condenser Stages Single Stage
Compressor Type Scroll
Liquid Line 3/8"
Suction Line 7/8"
Liquid Valve Size 3/8"
Suction Valve Size 7/8"
Electrical 208/230v 1 Phase 60Hz
Max Breaker Size 30 Amps
Min. Breaker Size 17.8 Amps
Tonnage 3 Ton
Connection Sweat
Height 39 1/2"
Width 29"
Depth 29"
Manual
What our Experts Think
  • Right‑Sized 3‑Ton Cooling: Provides 36,000 BTU capacity, ideal for mid‑sized homes and residential split systems needing dependable cooling performance.

  • Solid Efficiency: 14.3 SEER2 rating strikes a great balance between energy savings and cost‑effective performance compared to lower‑SEER units.

  • Reliable Single‑Stage Operation: Single‑stage compressor offers straightforward, dependable performance with fewer components and easier long‑term maintenance.

  • Modern R‑32 Refrigerant: Designed to use R‑32 refrigerant, delivering improved heat‑transfer efficiency and reduced environmental impact versus older refrigerants.

  • Durable Outdoor Construction: Rugged, weather‑resistant cabinet protects critical components and helps ensure long‑lasting outdoor service life.

  • Service‑Friendly Design: Accessible service valves and panels make installation and maintenance easier for HVAC professionals.


Q&A

Q: What cooling capacity and efficiency does the Goodman GLXS4BA3610 3 Ton Air Conditioner Condenser deliver?
A: The Goodman GLXS4BA3610 delivers 3 tons (36,000 BTU) of cooling with a 14.3 SEER2 efficiency rating, balancing solid performance and energy savings for many residential spaces.

Q: What refrigerant and compressor type does it use?
A: This condenser uses R‑32 refrigerant (a lower‑GWP option) and a single‑stage scroll compressor for reliable, consistent cooling.

Q: What are the key durability and protection features?
A: Standard features include a factory‑installed filter drier, sweat connection service valves with gauge access, high‑pressure switch, enclosed contactor, ground lug connection, and extended‑life capacitors for long‑term reliability.

Q: How is the outdoor cabinet built for weather resistance?
A: The unit has a powder‑coated galvanized steel cabinet with steel louver coil guard, removable grille top, and venturi airflow design, plus corrosion‑resistant finish tested for salt spray protection.

Q: What are the electrical and connection specifications?
A: It operates on 208/230 V single‑phase power, with standard 3/8″ liquid and 7/8″ suction line connections for typical residential installs.

Q: How quiet is this condenser during operation?
A: Typical sound levels are around 67 dB, helping ensure quieter outdoor operation compared with older lower‑efficiency units.

Maintenance Tips
  • Maintain at least 24 inches of clearance around the outdoor unit for proper airflow and efficient operation.

  • Clean the condenser coil regularly with low-pressure water to remove dirt and debris and maintain SEER2 14.3 efficiency.

  • Replace or clean indoor air filters every 1–3 months to reduce strain on the compressor and maintain airflow.

  • Inspect refrigerant lines and insulation for leaks, damage, or loose connections to ensure proper R‑32 operation.

  • Check electrical connections and disconnect box for corrosion, wear, or loose wiring.

  • Monitor unusual noises or vibrations from the compressor or fan motor as early indicators of maintenance needs.

  • Ensure the unit is level to prevent drainage issues and uneven cooling.

  • Keep the cabinet and coil guards clean and intact to protect components and maintain airflow.

  • Schedule annual professional HVAC service to inspect refrigerant levels, coils, and system controls.