Only a few left—secure yours before it’s gone for good!
Your items are reserved, but only for a limited time!
Grab it now at a discounted price before the deal ends!
$1,899.97 USD
$2,499.97 USD
$41,649.00 USD
$44,099.00 USD
$5,499.00 USD
$1,699.97 USD
$1,799.00 USD
$2,498.00 USD
$2,799.98 USD
$3,099.00 USD
$4,398.00 USD
$1,499.00 USD
The Goodman GLZS4BA3610 heat pump condenser is a standard efficiency, low-cost solution for an all-electric home when paired with a suitable heat pump coil or air handler. Just like all of Goodman's equipment, the GLZS4BA3610 is manufactured with high-quality materials to provide a superior comfort in your home.
Please note this is an outdoor unit only, for full system operation this needs to be paired with an indoor unit.
| 3 Ton 14.3 SEER2 Goodman Heat Pump - R32 | |
|---|---|
| SKU | GLZS4BA3610 |
| Weight (in lbs) | 211.000000 |
| Brand/Manufacturer | Goodman |
| Replaces | GSZ140361, GSZB403610 |
| HSPF2 | 7.8 |
| Cooling BTU | 36,000 |
| Heating BTU | 36,000 |
| Blower Motor | Single Speed PSC Motor |
| Decibel Level (dBA) | 75 |
| Horsepower | 1/6 HP |
| Refrigerant | R32 |
| SEER2 (Efficiency) | 14.3 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Line | 3/8" |
| Suction Line | 7/8" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Electrical | 208/230v 1 Phase 60 Hz |
| Max Breaker Size | 35 Amps |
| Min. Breaker Size | 21.5 Amps |
| Tonnage | 3 Ton |
| Connection | Sweat |
| Height | 35 3/4" |
| Width | 35 1/2" |
| Depth | 35 1/2" |
Manual
Balanced Cooling & Heating with R‑32 Compliance
The Goodman GLZS4BA4210 3 Ton / 36,000 BTU Heat Pump Condenser delivers 14.3 SEER2 cooling and ~7.8 HSPF2 heating performance using R‑32 refrigerant, helping reduce environmental impact while providing dependable year‑round comfort.
Reliable Single‑Stage Operation
A single‑stage scroll compressor ensures steady, consistent performance with fewer moving parts—ideal for homeowners who want straightforward heating & cooling without complex modulation.
SmartShift Defrost for Quiet Heating
Built‑in SmartShift technology enables quiet and reliable defrost cycles in colder weather, improving comfort and reducing noise compared with basic heat pump designs.
Durable Outdoor Construction
Heavy‑gauge galvanized steel cabinet with a powder‑paint finish and steel louver coil guard enhances outdoor durability and corrosion resistance, while a removable grille‑style top offers easy service access.
Factory‑Installed Protection & Service Features
Comes with a bi‑flow liquid‑line filter drier, suction‑line accumulator, crankcase heater, and muffler, plus service valves with easy gauge port access, helping simplify maintenance and protect internal components.
Quiet, Code‑Certified Performance
AHRI certification and ETL listing confirm performance and safety standards, and this unit operates at around 72–75 dBA—balanced for residential comfort without excessive noise.
Q1: What type of system is the Goodman GLZS4BA4210?
A: It’s an outdoor heat pump condenser for a split‑system HVAC that provides both heating and cooling (must be paired with a matched indoor coil or air handler).
Q2: What size and capacity does this unit have?
A: This model is rated as 3.5 tons (~42,000 BTU) of cooling and heating capacity, making it suitable for medium‑sized residential homes.
Q3: What efficiency ratings does it offer?
A: It delivers 14.3 SEER2 cooling efficiency and about 7.8 HSPF2 heating performance, providing reliable energy performance year‑round.
Q4: Which refrigerant does it use?
A: The condenser uses R‑32 refrigerant, a modern, lower‑global‑warming alternative that meets current environmental and efficiency standards.
Q5: What compressor and fan features are included?
A: It’s equipped with a single‑stage scroll compressor and a single‑speed PSC condenser fan motor for dependable operation.
Q6: What protective and service features does it include?
A: Factory‑installed features include bi‑flow liquid‑line filter drier, suction‑line accumulator, crankcase heater, and high/low‑pressure switches, plus removable grille‑style top and steel louver coil guard for service access and durability.
Q7: What are the installation specs?
A: The unit operates on 208/230 V single phase with standard 3/8″ liquid and 1⅛″ suction lines, is fully charged for up to ~15 ft of tubing, and has service valves with easy gauge access.
Q8: What is the sound level and construction like?
A: Typical sound levels are around 72 dBA. It’s built with a heavy‑gauge galvanized‑steel cabinet and architectural gray powder‑coat finish for long outdoor life.
Clean & Clear Outdoor Unit Routinely – Remove leaves, grass, and debris from around the condenser and gently rinse the coil with a garden hose (low pressure) to maintain heat exchange efficiency and airflow. Maintain ~2 ft minimum clearance around the unit.
Check Air Filters Monthly – Replace or clean filters in the indoor air handler every 1–3 months; restricted airflow forces the outdoor condenser to work harder.
Inspect Refrigerant Lines & Insulation – Verify R32 refrigerant lines are intact, insulated, and leak‑free; improper charge reduces SEER2 performance.
Inspect Electrical & Mechanical Components Annually – Have a technician tighten electrical connections, check capacitors/contactors, and inspect fan motor operation.
Ensure Unit Level & Pad Stable – A level condenser pad prevents undue stress on refrigerant lines and mechanical components, helping avoid premature wear.
Annual Professional Tune‑Up – A qualified HVAC tech should check refrigerant charge, measure pressures and temperatures, clean coils, and verify efficient heat pump operation