Only a few left—secure yours before it’s gone for good!
Your items are reserved, but only for a limited time!
Grab it now at a discounted price before the deal ends!
$1,899.97 USD
$2,499.97 USD
$41,649.00 USD
$44,099.00 USD
$5,499.00 USD
$1,699.97 USD
$1,799.00 USD
$2,498.00 USD
$2,799.98 USD
$3,099.00 USD
$4,398.00 USD
$1,499.00 USD
A Goodman combination system is a great choice to keep your home comfortable all season long. With tons of extra features and a great price, a Goodman air conditioner split system is the perfect choice for all of your cooling needs.
| SKU | GLXS4BA4810 |
|---|---|
| Weight | 226.000000 |
| Manufacturer | Goodman |
| Replaces | GSXN404810 |
| Cooling BTU | 48,000 |
| Blower Motor | Single Speed PSC Motor |
| Decibel Level (dBA) | 73 |
| Horsepower | 1/6 HP |
| Refrigerant | R32 |
| SEER2 | 14.3 |
| Condenser Stages | Single Stage |
| Compressor Type | Scroll |
| Liquid Line | 3/8" |
| Suction Line | 1 1/8" |
| Liquid Valve Size | 3/8" |
| Suction Valve Size | 7/8" |
| Electrical | 208/230v 1 Phase 60Hz |
| Max Breaker Size | 40 Amps |
| Min. Breaker Size | 25.2 Amps |
| Tonnage | 4 Ton |
| Connection | Sweat |
| Height | 35 3/4" |
| Width | 35 1/2" |
| Depth | 35 1/2" |
Strong 4-Ton Cooling Capacity
This split system delivers 48,000 BTU (4 tons) of cooling power, making it ideal for medium-to-large homes or larger residential zones that require reliable whole-home air conditioning.
Balanced 14.5 SEER2 Energy Efficiency
With a 14.5 SEER2 rating, the system offers a solid mix of energy efficiency and cost-effective performance while meeting modern HVAC efficiency standards.
Reliable Single-Stage Scroll Compressor
The outdoor condenser uses a single-stage scroll compressor, designed for dependable cooling output, simple operation, and long-term durability.
Modern R-32 Refrigerant Technology
The system uses R-32 refrigerant, which supports newer HVAC efficiency requirements and improved environmental performance compared to older refrigerant systems.
Multi-Positional Air Handler Flexibility
The AMST60DU1300 air handler supports vertical or horizontal installation, allowing flexible placement in closets, basements, or attic spaces depending on the home layout.
Efficient Multi-Speed ECM Blower Motor
A direct-drive multi-speed ECM blower automatically adjusts airflow (about 1,215–1,970 CFM) to improve comfort, efficiency, and airflow control.
Durable Coil and Cabinet Construction
The system includes enhanced aluminum fin coils with copper tubing and a powder-coated galvanized steel cabinet, helping resist corrosion and improve heat transfer performance.
Q: What cooling capacity does this system provide?
A: This system delivers 48,000 BTU (4 tons) of cooling, making it suitable for medium-to-large homes depending on insulation, layout, and climate conditions.
Q: What is the SEER2 efficiency rating?
A: The system offers 14.5 SEER2 efficiency, providing reliable cooling performance while meeting modern energy efficiency standards.
Q: What refrigerant does this air conditioning system use?
A: It uses R-32 refrigerant, a newer refrigerant designed to improve efficiency and reduce environmental impact compared to older refrigerants.
Q: What type of compressor does the condenser use?
A: The outdoor unit includes a single-stage scroll compressor, designed for dependable cooling and long-term durability.
Q: What does “multi-positional” mean for the air handler?
A: The AMST60DU1300 air handler supports vertical or horizontal installation, allowing flexible placement in closets, attics, basements, or utility rooms.
Q: What type of blower motor is included?
A: The air handler features a direct-drive ECM blower motor with multiple speed settings, helping improve airflow efficiency and comfort.
Q: What electrical requirements does this system have?
A: The system operates on 208/230V single-phase power, which is standard for most residential HVAC installations.
Q: How quiet is the condenser during operation?
A: The outdoor unit typically operates at around 73 dBA, which is comparable to most standard residential AC condensers.
Q: What warranty does this Goodman system include?
A: Goodman typically provides a 10-year limited parts and compressor warranty when the system is properly registered after installation.
Q: Is this system certified for performance and safety?
A: Yes. The system components are AHRI-certified and ETL-listed, ensuring tested performance and compliance with HVAC standards.
Replace the air filter every 1–3 months to maintain airflow and cooling efficiency.
Keep the outdoor condenser unit clear of leaves, dirt, and debris for proper heat transfer.
Maintain 2–3 feet of clearance around the outdoor unit to ensure unrestricted airflow.
Clean the evaporator and condenser coils periodically to prevent efficiency loss.
Check the condensate drain line regularly to prevent clogs and water buildup.
Inspect refrigerant lines and insulation for damage or wear.
Ensure supply and return vents are open and unobstructed throughout the home.
Listen for unusual noises such as rattling or buzzing that may indicate loose parts.
Check thermostat operation and settings to maintain efficient cooling cycles.
Schedule annual professional HVAC service to inspect refrigerant levels, electrical components, and overall system performance.