Goodman - 4 Ton/60,000 BTU Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPGM34806031
The Goodman GPGM34806031 is a gas heat and electric AC packaged unit, ready for any application where it is not convenient to have an indoor furnace or air handler. At 13.4 SEER2 and 80% AFUE, the GPGM34806031 is an inexpensive option with a standard efficiency designed for rooftop and next-to-building applications.
Features
- 4 ton, 60,000 BTU packaged unit
- 13.4 SEER2, 80% AFUE
- Downflow or horizontal discharge installation options
- Fully charged and ready to install
- Low sound output
- Low NOx compliant
Specifications
| SKU |
GPGM34806031 |
| Weight (in lbs) |
518.000000 |
| AHRI Certificate Number |
209319544 |
| Brand/Manufacturer |
Goodman |
| Replaces |
GPG1448060M41 |
| Furnace Efficiency / AFUE |
80% |
| Cooling BTU |
46,500 BTU |
| Heating BTU |
60,000 BTU |
| Blower Motor |
Multi-Speed |
| Maximum CFM |
1525 |
| Decibel Level (dBA) |
78 decibels |
| Configuration |
Downflow/Horizontal |
| Refrigerant |
R32 |
| SEER2 (Efficiency) |
13.4 |
| Condenser Stages |
Single Stage |
| Compressor Type |
Scroll |
| Electrical |
208 / 230 V. 1 Phase 60 Hz |
| Max Breaker Size |
50 amps |
| Tonnage |
4 Ton |
| Fuel Type |
Natural Gas |
| Height |
42 1/2" |
| Width |
47" |
| Depth |
51" |
Owner's Manual
What our Experts Think
-
Allāināone packaged comfort solution: The Goodman 4āÆTon Gas Packaged Unit (Model GPGM34806031) delivers both cooling and natural gas heating in a single outdoor system ā no separate indoor furnace or air handler needed.
-
Practical everyday efficiency: With a 13.4āÆSEER2 cooling rating and about 80ā81āÆ% AFUE heating, this unit hits standard energy performance targets, helping balance operating costs with upfront affordability.
-
Rā32 refrigerant for modern performance: Precharged with Rā32 refrigerant, it improves thermodynamic efficiency and reduces environmental impact compared with older refrigerants.
-
Straightforward, reliable operation: A singleāstage scroll compressor and multiāspeed ECM blower motor provide consistent cooling and balanced airflow without complex staging, ideal for everyday residential or light commercial use.
-
Flexible placement and installation: Designed for horizontal or downflow discharge, this packaged configuration works well on rooftops or beside buildings where space is limited.
-
Durable build with noise considerations: The heavyāgauge steel cabinet with insulation helps reduce sound output while protecting internal components for longāterm reliability.
-
Good warranty support: Offers a 10āyear limited parts and compressor warranty with registration, plus a long heat exchanger warranty that boosts confidence in longāterm use.
-
Valueāoriented choice for packaged systems: Experts view this model as a costāeffective, straightforward HVAC package thatās ideal for applications where simplicity, durability, and balanced performance matter most.
Q&A
Q: What type of HVAC system is the Goodman GPGM34806031?
A: The GPGM34806031 is a 4-ton gas packaged unit combining heating and cooling in a single outdoor unit, ideal for homes or small commercial spaces where indoor air handler space is limited.
Q: How large of a space is this unit suitable for?
A: A 4-ton system (48,000ā60,000 BTU) is generally suitable for larger homes or small commercial areas around 1,800ā2,400 sq. ft., depending on insulation, layout, and climate.
Q: How energy efficient is this system?
A: This packaged unit offers 13.4 SEER2 cooling efficiency and high-efficiency gas heating, delivering reliable comfort with moderate energy savings.
Q: What refrigerant does this unit use?
A: The unit uses Rā32 refrigerant, an environmentally-friendly refrigerant that improves efficiency and reduces greenhouse gas impact.
Q: Is this a single-stage or multi-stage system?
A: The GPGM34806031 is a single-stage unit, providing consistent operation at full capacity for heating and cooling.
Q: What electrical requirements does this system have?
A: This unit operates on 230V single-phase power, standard for residential and light commercial installations.
Maintenance Tips
-
Replace air filters every 1ā3 months: Keeps airflow optimal, protects the blower, and improves indoor air quality.
-
Keep the unit exterior clear: Maintain 2ā3 ft clearance and remove debris, leaves, or grass to ensure proper airflow and efficient cooling.
-
Inspect the evaporator coil and condensate pan: Periodically check for dust, dirt, or clogs to prevent water leaks and reduced cooling performance.
-
Check refrigerant line insulation: Ensure suction line insulation is intact to maintain energy efficiency.
-
Keep supply and return vents unobstructed: Ensures balanced airflow and consistent comfort throughout the home.
-
Schedule annual professional service: A certified HVAC technician should inspect the heat exchanger, blower motor, refrigerant levels, and safety controls yearly.
-
Maintain clear surrounding space: Keep the area around the packaged unit free of clutter to allow safe operation and proper airflow.