Skip to product information
1 of 10

Goodman

Goodman - 4 Ton/80,000 BTU Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPGM34808031

Goodman - 4 Ton/80,000 BTU Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPGM34808031

1 Review

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price Sale price $6,090.00
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$100.00

$30.00

$200.00

$70.00

Add-Ons Bundle

$100.00

$30.00

$200.00

$70.00

Bundle Offer

$300.00

$100.00

Recently Viewed

Goodman - 4 Ton/80,000 BTU Gas Packaged Unit - 13.4 SEER2 - Single Stage - R32 - 230V - GPGM34808031

The Goodman GPGM34808031 is a gas heat and electric AC packaged unit, ready for any application where it is not convenient to have an indoor furnace or air handler. At 13.4 SEER2 and 80% AFUE, the GPGM34808031 is an inexpensive option with a standard efficiency designed for rooftop and next-to-building applications.

Features
  • 4 ton, 80,000 BTU packaged unit
  • 13.4 SEER2, 80% AFUE
  • Downflow or horizontal discharge installation options
  • Fully charged and ready to install
  • Low sound output
  • Low NOx compliant
Specifications
4 Ton 13.4 SEER2 80,000 BTU Goodman Gas Packaged Unit - R32
SKU GPGM34808031
Weight (in lbs) 523.000000
AHRI Certificate Number 209319544
Brand/Manufacturer Goodman
Replaces GPU1448080M41, GPG1448080M41
Furnace Efficiency / AFUE 80%
Cooling BTU 46,500 BTU
Heating BTU 80,000 BTU
Blower Motor Multi-Speed
Maximum CFM 1525
Decibel Level (dBA) 78 decibels
Configuration Downflow/Horizontal
Refrigerant R32
SEER2 (Efficiency) 13.4
Condenser Stages Single Stage
Compressor Type Scroll
Electrical 208 / 230 V. 1 Phase 60 Hz
Max Breaker Size 50 amps
Tonnage 4 Ton
Fuel Type Natural Gas
Height 42 1/2"
Width 47"
Depth 51"
Manual
What our Experts Think
  • All‑in‑One Heating & Cooling Solution
    The Goodman GPGM34808031 is a 4 Ton, 80,000 BTU gas‑electric packaged HVAC system featuring both heating and cooling in one outdoor unit—ideal where indoor furnace/air handler space is limited.

  • Balanced Comfort with Standard Efficiency
    With 13.4 SEER2 cooling and ~80–81 % AFUE heating, it delivers seasonal cooling efficiency and dependable gas heat performance that meets national performance baselines.

  • R‑32 Refrigerant for Better Environmental Impact
    Factory‑charged with R‑32 refrigerant, it supports modern HVAC regulatory trends and lower global warming potential than older refrigerants without sacrificing performance.

  • Versatile Installation Options
    A downflow/horizontal airflow design lets technicians adapt the unit to roof‑mounted or ground‑level setups, adding flexibility for different home layouts.

  • Dependable Components Inside
    Featuring a single‑stage scroll compressor, multi‑speed ECM blower motor, and heavy‑gauge steel cabinet with sound‑insulation, this unit promotes steady airflow, durability, and quieter operation.

  • Low NOx Compliance & Weather‑Ready Build
    Built to meet Low NOx emission standards and crafted with corrosion‑resistant steel construction, it’s suited for rooftop or outdoor installations in diverse climates.

  • Installer‑Friendly & Ready to Go
    Comes factory‑charged and pre‑configured, reducing setup time for HVAC pros and helping ensure smooth installation and startup.


Q&A

Q1: What type of HVAC unit is this?
A: The Goodman GPGM34808031 is a 4 ton gas‑electric packaged HVAC system that combines both cooling and heating in one outdoor unit — no separate indoor furnace or coil required.

Q2: What are the heating and cooling capacities?
A: It delivers 80,000 BTU of natural gas heating and 4 tons (~46,000 BTU) of cooling capacity in a single packaged system for year‑round comfort.

Q3: What efficiency ratings does it have?
A: This unit offers 13.4 SEER2 cooling efficiency and approximately 80–81% AFUE heating efficiency, balancing performance with cost‑effective operation.

Q4: Which refrigerant is used?
A: The packaged unit is factory‑charged with R‑32 refrigerant, a modern, lower‑environmental‑impact choice for residential cooling.

Q5: How is airflow configured?
A: It supports downflow or horizontal discharge airflow, giving flexibility for different rooftop or outdoor installations.

Q6: What kind of compressor and motor does it use?
A: A single‑stage scroll compressor provides reliable cooling start‑to‑finish, paired with a multi‑speed ECM blower motor for balanced air delivery and improved comfort.

Q7: What are its key construction and sound features?
A: Built with a heavy‑gauge steel cabinet and sound‑insulated panels, it’s designed for quiet outdoor operation and durability in varied climates.

Q8: What electrical and installation specs should I know?
A: The unit runs on 208/230 V single‑phase power, typically requiring up to a 50 A breaker. It’s fully charged and ready for installation with minimal setup time.

Maintenance Tips
  • Change or Clean Air Filters Every 1–3 Months – Accessible filters protect internal coils and blower motors, keeping airflow strong and reducing energy costs.

  • Clean Evaporator & Condenser Coils Annually – Dust buildup on the all‑aluminum coil lowers heat transfer and SEER2 efficiency; professional cleaning preserves performance.

  • Inspect Condensate Drain & Pan – Clear the drain line to prevent water buildup and mold growth, especially in cooling seasons.

  • Check Electrical Connections & Controls – Tighten loose terminals, inspect wiring, and examine capacitors/contactors to reduce breakdown risk.

  • Ensure Proper Airflow Pathways – Keep vents, louvers, and surrounding unit area clear of debris; unobstructed airflow improves comfort and efficiency.

  • Monitor Refrigerant Lines & R32 Charge – Have a professional verify R32 refrigerant levels and insulation to maintain cooling capacity and prevent compressor stress.

  • Schedule Annual Professional HVAC Service – Annual tune‑ups help detect combustion, heat exchanger, and burner issues early, optimizing heating and cooling year‑round.