Only a few leftâsecure yours before itâs gone for good!
Your items are reserved, but only for a limited time!
Grab it now at a discounted price before the deal ends!
$1,899.97 USD
$2,499.97 USD
$41,649.00 USD
$44,099.00 USD
$5,499.00 USD
$1,699.97 USD
$1,799.00 USD
$2,498.00 USD
$2,799.98 USD
$3,099.00 USD
$4,398.00 USD
$1,499.00 USD
The GD9T800804BX Goodman gas furnace features high-quality construction and efficient operation at a great value. The GD9T800804BX two-stage, 9-speed furnace utilizes Goodman's superior heat exchanger design to provide efficient, reliable heating to your home. If you're looking to cut your energy bills and improve your comfort without breaking the bank, your search stops with the Goodman GD9T800804BX.
| Goodman 80% 80,000 BTU Two Stage Gas Furnace - 17.5" Width - Downflow / Horizontal | |
|---|---|
| SKU | GD9T800804BX |
| Weight (in lbs) | 121.000000 |
| AHRI Certificate Number | 215358014 |
| Airflow Direction | Downflow/Horizontal |
| Exhaust Flue Requirement | Metal |
| R-32 Compliant | Yes |
| Brand/Manufacturer | Goodman |
| Product Features | Low NOx, New Refrigerant Compliant |
| Furnace Efficiency / AFUE | 80% |
| Heating BTU | 80,000 |
| Blower Motor | 9 Speed - ECM |
| Maximum CFM | 1600 |
| Configuration | Downflow/Horizontal |
| Electrical | 115 V. 1 Phase 60 Hz |
| Max Breaker Size | 20 Amps |
| Min. Breaker Size | 11.3 Amps |
| Low NOx | Low NOx |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Height | 33 3/8" |
| Width | 17.5" |
| Depth | 28" |
Modern LowâNOx Heating for Cleaner Emissions
The Goodman GD9T800804BX 80,000âŻBTU Gas Furnace meets Low NOx emission standards, reducing nitrogen oxides for cleaner indoor/outdoor airâimportant for areas with stricter environmental requirements.
Balanced Comfort with TwoâStage Operation
The twoâstage gas valve delivers gentler lowâfire heat during mild weather and full output on cold days, enhancing comfort consistency and efficiency compared with basic singleâstage units.
Efficient Airflow & Quiet Operation
A 9âspeed ECM blower motor provides steady, energyâefficient airflow and quieter operation across seasons, while the twoâspeed inducedâdraft blower balances performance and sound control.
Durable, InstallerâFriendly Design
Fully insulated heavyâgauge steel cabinet with bakedâenamel finish, removable bottom panel for flexible return placement, and left/right service connections simplify installation and longâterm maintenance.
Flexible Placement for Tight Spaces
Designed for downflow or horizontal installs in attics, closets, and basements, this 17.5âł wide furnace fits common tight spaces without costly duct modifications.
Reliable Ignition & Smart Diagnostics
Features like the SureStart silicon nitride igniter and builtâin selfâdiagnostic control board improve reliability and make troubleshooting faster for technicians.
Q1: What heating capacity and efficiency does this furnace deliver?
A: The Goodman GD9T800804BX offers 80,000âŻBTU input (~64,000âŻBTU output) with an 80% AFUE rating, converting most fuel into usable heat for yearâround comfort.
Q2: What type of operation and stages does it use?
A: It features a twoâstage gas valve, providing quieter, more economical heating than singleâstage units.
Q3: What installation orientations are supported?
A: This model supports downflow and horizontal installation, offering flexibility for attics, crawl spaces, or closets.
Q4: Does it have a lowâemission burner?
A: Yes â this is a Low NOx furnace compliant with stricter nitrogenâoxide emission standards in many regions.
Q5: What motor and airflow features are included?
A: It includes a 9âspeed ECM blower motor for smooth airflow, quieter performance, and better comfort control.
Q6: What construction and control features does it offer?
A: Comes with a heavyâgauge insulated steel cabinet, SureStartÂŽ silicon nitride igniter for long life, selfâdiagnostic control board, and twoâspeed inducedâdraft blower.
Q7: What are the electrical and venting requirements?
A: Runs on 115âŻV, singleâphase power with metal flue venting required for 80% AFUE furnaces.
Q8: What fuel types are supported?
A: Compatible with natural gas and propane (LP) with conversion kit.
Replace Air Filters Every 1â3âŻMonths â Check the return air filter monthly and replace often to maintain airflow, protect the blower, and prevent overheating or flame rollout. Dirty filters reduce efficiency and can stress internal components.
Annual Professional Inspection â Have a qualified HVAC technician inspect burners, heat exchanger, ignition system, gas pressure, and venting before the heating season to ensure safe and efficient operation.
Clear Area Around Furnace â Keep the space around the furnace free of dust, debris, and combustible items to support airflow and reduce fire risk.
Check Exhaust & Vent Paths â Ensure metal flue venting remains unobstructed and wellâsealed; blockages or leaks can cause combustion issues or carbon monoxide hazards.
Inspect Electrical & Control Components â Periodically inspect control board connectors, limit switches, and wiring for tight, corrosionâfree connections.
Test Safety Devices & Thermostat â Confirm flame rollout sensors, limit switches, and thermostat settings work properly; test carbonâmonoxide detectors for safety.
Document All Maintenance â Track filter changes, professional services, and any repairs to support warranty coverage and future troubleshooting.