Only a few leftâsecure yours before itâs gone for good!
Your items are reserved, but only for a limited time!
Grab it now at a discounted price before the deal ends!
$1,899.97 USD
$2,499.97 USD
$41,649.00 USD
$44,099.00 USD
$5,499.00 USD
$1,699.97 USD
$1,799.00 USD
$2,498.00 USD
$2,799.98 USD
$3,099.00 USD
$4,398.00 USD
$1,499.00 USD
The GDVT800805CX gas furnace is from one of the top-of-the-line series by Goodman. Considered one of the best of the best, this furnace has a two stage burner and a variable speed blower motor. With the best durability and reliability that Goodman 80% efficient furnaces have to offer, and a lower emissions output to match the low NOx compliance regulations in California, we are proud to offer you the Goodman GDVT800805CX gas furnace.
| Goodman 80% 80,000 BTU Variable Speed Two Stage Gas Furnace - 21" Width - Downflow / Horizontal | |
|---|---|
| SKU | GDVT800805CX |
| Weight (in lbs) | 125.000000 |
| Airflow Direction | Downflow/Horizontal |
| Exhaust Flue Requirement | Metal |
| R-32 Compliant | Yes |
| Brand/Manufacturer | Goodman |
| Product Features | Low NOx, New Refrigerant Compliant |
| Furnace Efficiency / AFUE | 80% |
| Heating BTU | 80,000 |
| Blower Motor | Variable Speed |
| Maximum CFM | 2000 |
| Configuration | Downflow/Horizontal |
| Low NOx | Low NOx |
| Burner Stages | Two |
| Fuel Type | Propane, Natural Gas |
| Height | 33 3/8" |
| Width | 21" |
| Depth | 28" |
Balanced Comfort with VariableâSpeed & TwoâStage Heat
The Goodman GDVT800805CX is an 80,000âŻBTU, 80âŻ% AFUE gas furnace that combines a twoâstage gas valve with a variableâspeed ECM blower to deliver smoother, quieter heat and more consistent indoor temperatures than traditional singleâstage units.
Integrated Smart Controls & Diagnostics
With ComfortBridge⢠communicating technology and CoolCloud⢠Bluetooth commissioning/diagnostics, this model makes system setup and service easier for installers and HVAC pros while helping optimize performance.
Quiet, Efficient Airflow Operation
The variableâspeed blower gently ramps airflow up or down based on heating demand, yielding quieter operation, improved humidity management, and balanced comfort distribution across living spaces.
Low NOx & R32âCompliant Design
Built to meet Low NOx emissions standards and compatible with Râ32 refrigerant systems, this furnace suits modern HVAC requirements and helps minimize environmental impact.
Durable Construction & Smart Diagnostics
A heavyâduty aluminized steel tubular heat exchanger, SureStartÂŽ silicon nitride igniter, and selfâdiagnostic control board support longâlasting performance and easier service troubleshooting.
Flexible Installation Options
Its multiâposition design works in downflow or horizontal orientations, fitting a variety of home layouts and installation configurations with convenient left/right connections for gas and electrical service.
Q1: What size and efficiency does this furnace deliver?
A: The Goodman GDVT800805CX delivers 80âŻ000âŻBTU input heating with an 80% AFUE rating, meaning it converts most of the fuel into heat for efficient performance in mediumâsized homes.
Q2: What heating stages and motor technologies does it include?
A: It features a twoâstage gas valve combined with a variableâspeed ECM blower motor, resulting in quieter, more consistent heat and smoother airflow compared with singleâstage or singleâspeed models.
Q3: What installation orientations are supported?
A: This furnace supports downflow or horizontal installation, making it versatile for attics, crawl spaces, and closets where space or duct layout demands change.
Q4: What is the fuel type and emissions rating?
A: It runs on natural gas (convertible to propane with an optional kit) and is Low NOx compliant, producing lower nitrogenâoxide emissions in many regions.
Q5: What are the key construction features?
A: The unit includes a heavyâgauge steel cabinet, durable heat exchanger, silicon nitride igniter, and selfâdiagnostic control board with ComfortBridge⢠compatibility for system communication and diagnostics.
Q6: What electrical requirements does it have?
A: It runs on 115âŻV singleâphase power with electrical protection typically sized based on local installation requirements.
Q7: What are the blower and airflow capabilities?
A: The variableâspeed blower can deliver up to ~2âŻ000âŻCFM, adjusting airflow to match heating and cooling demands for improved comfort and quieter operation.
Replace Air Filters Every 1â3âŻMonths â Clean filters ensure proper airflow, protect the blower and heat exchanger, and support quiet, efficient variableâspeed heating. Dirty filters can reduce system efficiency and lead to higher operating costs.
Annual Professional Inspection â A qualified HVAC technician should check burners, heat exchanger, ignition system, gas pressure, and venting each fall to maintain safe, efficient twoâstage operation and long equipment life.
Check Area & Vent Clearance â Keep at least 2â3âŻft of clear space around the furnace and ensure intake/exhaust vent paths remain free of obstructions like dust, debris, or blockages.
Inspect Electrical & Control Components â During service, have the technician tighten electrical connections, check the variableâspeed ECM motor, ComfortBridge⢠controls, and diagnostic system for reliable operation.
Test Thermostat & Safety Devices â Verify thermostat accuracy and test safety devices (limit switches, CO detectors) to ensure proper staging and safe combustion.
Document Maintenance â Log filter changes and professional services to support warranty and track longâterm performance.