Skip to product information
1 of 11

Goodman

Goodman - 80,000 BTU 80% Variable Speed Gas Furnace - 21" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GRVT800804CN

Goodman - 80,000 BTU 80% Variable Speed Gas Furnace - 21" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GRVT800804CN

1 Review

Only left!

image

Free Delivery

image

Limited Stocks

In Stock - Ready to be Shipped

Regular price Sale price $2,254.00
Shipping calculated at checkout.

Quantity

View full details
SALE ENDS IN
07 HRS
23 MINS
28 SECS
DON'T MISS IT!

Popular Add on

$100.00

$30.00

$200.00

$70.00

Add-Ons Bundle

$100.00

$30.00

$200.00

$70.00

Bundle Offer

$300.00

$100.00

Recently Viewed

Goodman - 80,000 BTU 80% Variable Speed Gas Furnace - 21" Width - Upflow / Horizontal - Two Stage - 115V - R32 - GRVT800804CN

The GRVT800804CN gas furnace is from one of the top-of-the-line series by Goodman. Considered one of the best of the best, this furnace has a two stage burner and a variable speed blower motor. With the best durability and reliability that Goodman 80% efficient furnaces have to offer, we are proud to offer you the Goodman GRVT800804CN gas furnace.

Features
  • This furnace is ideal to heat a small to medium house (in average climate conditions)
  • 80,000 BTU 80% AFUE two stage variable speed natural gas furnace
  • Requires metal flue venting
  • Can be used in the upflow or horizontal orientation
  • Can be converted to propane with an LP conversion kit (sold separately)
  • Innovative design for electrical efficiency, safety, and lower sound output
Specifications
SKU GRVT800804CN
Weight (in lbs) 118.000000
Airflow Direction Upflow/Horizontal
Exhaust Flue Requirement Metal
R-32 Compliant Yes
Brand/Manufacturer Goodman
Product Features New Refrigerant Compliant
Furnace Efficiency / AFUE 80%
Heating BTU 80,000
Blower Motor Variable Speed
Maximum CFM 1600
Configuration Upflow/Horizontal
Burner Stages Two
Fuel Type Propane, Natural Gas
Height 33 3/8"
Width 21"
Depth 28"
Warranty Lifetime Heat Exchanger, 10 Years Unit Replacement, and 10 Years Parts with Online Registration
Tonnage 2.5 Ton
Connection Sweat
Height 32"
Width 29"
Depth 29"

 

Owner's Manual

What our Experts Think
  • Variable‑Speed Comfort Control
    • The variable‑speed blower motor continuously adjusts airflow to match demand, improving temperature consistency, quieter operation, and better air circulation compared with single‑stage units.

  • Two‑Stage Heating Performance
    • With two heating stages, the furnace runs at lower capacity for mild days and full power when it’s cold, reducing cycling and enhancing comfort.

  • Good Seasonal Efficiency
    • 80% AFUE provides solid heating performance at an affordable price point — a dependable choice for moderate climates.

  • Flexible Installation Options
    • Designed for upflow or horizontal configurations, making it suitable for attic, closet, or crawl‑space setups where space constraints matter.

  • Standard 115 V Operation
    • Uses everyday 115‑volt power, simplifying electrical connections during installation.

  • R‑32 System Compatibility
    • While the furnace itself doesn’t use refrigerant, pairing it with R‑32 air conditioning equipment supports modern efficiency goals and environmental performance.


Q&A

Q: What heating capacity does this furnace provide?
A: This unit delivers 80,000 BTU of heating output, ideal for medium homes and residential spaces.

Q: How efficient is this furnace?
A: It operates at 80% AFUE, converting 80% of fuel into heat for reliable, cost‑effective performance.

Q: What type of blower and staging does it have?
A: Features a variable‑speed ECM blower and two‑stage gas valve for smoother temperature control, quieter operation, and improved airflow.

Q: What installation orientations are supported?
A: Supports both upflow and horizontal installation, offering flexibility for basements, attics, closets, or crawlspaces.

Q: What fuel and power requirements are needed?
A: Runs on natural gas (propane convertible) and uses 115 V electrical power.

Q: Is this model environmentally compliant?
A: Designed for standard emissions compliance and paired with R‑32 compatible systems in matched installations.

Q: Does it support advanced diagnostics or smart thermostats?
A: Compatible with ComfortBridge™ enabled controls and most modern thermostats for optimized performance.


Maintenance Tips
  • Replace or Clean Air Filters
    Inspect monthly; replace every 1–3 months to maintain airflow and energy efficiency.

  • Inspect Burner and Heat Exchanger
    Annual professional inspection ensures safe operation and proper 80% AFUE performance.

  • Clean Blower and Fan Assembly
    Dust buildup reduces airflow and efficiency; schedule annual cleaning.

  • Check Thermostat Operation
    Ensure proper calibration and smooth operation of the two-stage system.

  • Maintain Ductwork and Vents
    Clear obstructions in upflow or horizontal configurations for even heating.

  • Inspect Electrical Connections
    Verify wiring is secure; have a technician check for wear or corrosion during yearly service.

  • Schedule Annual Professional Maintenance
    Technician should check gas pressure, blower performance, and safety controls to extend furnace life.